2010•Journal of Control Engineering and Applied InformaticsRequires access

Two Design Procedures for a Time-Delay Control System

V. Cartoaje, Alina Simona Baiesu

Open publisher page 4 citations

Abstract

This paper deals with two design procedures of a control system for a proportional or integrator time-delay plant using a suitable placement of the closed-loop poles to have a small response time, a zero or small overshoot and a given magnitude ratio of the controller output to a step reference or disturbance. To obtain these performances, the both controller design procedures provide a unique solution for the closed-loop pole placement, such that the open-loop system is of simple integrator type (with one pole in origin) to have zero steady-state error to a step input. Three numerical examples for time-delay plants of proportional and integrator type are given to illustrate the effectiveness of the proposed control procedures.

About this research paper

What this paper is about

This paper deals with two design procedures of a control system for a proportional or integrator time-delay plant using a suitable placement of the closed-loop poles to have a small response time, a zero or small overshoot and a given magnitude ratio of the controller output to a step reference or disturbance. To obtain these performances, the both controller design procedures provide a unique solution for the closed-loop pole placement, such that the open-loop system is of simple integrator type (with one pole in origin) to have zero steady-state error to a step input. Three numerical examples for time-delay plants of proportional and integrator type are given to illustrate the effectiveness of the proposed control procedures.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper deals with two design procedures of a control system for a proportional or integrator time-delay plant using a suitable placement of the closed-loop poles to have a small response time, a zero or small overshoot and a given magnitude ratio of the controller output to a step reference or disturbance. To obtain these performances, the both controller design procedures provide a unique solution for the closed-loop pole placement, such that the open-loop system is of simple integrator type (with one pole in origin) to have zero steady-state error to a step input. Three numerical examples for time-delay plants of proportional and integrator type are given to illustrate the effectiveness of the proposed control procedures.

Key concepts: Integrator, Control theory (sociology), Overshoot (microwave communication), Controller (irrigation), Full state feedback, Step response, Open-loop controller, Control system