Comparison of building energy codes in Australia, United States and China for Australian commercial building energy conservation.
Yunlong Ma, Wendy Miller, Suvash C. Saha, Lisa Guan
Abstract
Open-access reader
Yunlong Ma, Wendy Miller, Suvash C. Saha, Lisa Guan
Abstract
Open-access reader
Building energy codes have been widely implemented in the world to regulate energy consumption and CO2 emissions from the building sector. In order to assess the impacts of building energy codes on Australian building performance, this paper has compared the energy efficiency requirements of the Building Code of Australia (BCA) with the USA ASHRAE Standard 90.1 and Chinese GB50189, in terms of the building envelope, HVAC chiller efficiency, internal load density, and HVAC temperature set-points. Then, the whole building energy performance simulation has been conducted using EnergyPlus for a typical large office building in Brisbane to contrast differences in efficiency requirements of building energy codes within three countries. The results have shown that the GB50189-2015 and ASHRAE 90.1-2016 demonstrated 25.0% and 20.8% annual energy savings respectively compared to the BCA 2016, together with 312,429kg and 259,955kg annual CO2 emissions reduction respectively. In light of this, recommendations for further revision of the Australian building energy code have been provided.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Building energy codes have been widely implemented in the world to regulate energy consumption and CO2 emissions from the building sector. In order to assess the impacts of building energy codes on Australian building performance, this paper has compared the energy efficiency requirements of the Building Code of Australia (BCA) with the USA ASHRAE Standard 90.1 and Chinese GB50189, in terms of the building envelope, HVAC chiller efficiency, internal load density, and HVAC temperature set-points. Then, the whole building energy performance simulation has been conducted using EnergyPlus for a typical large office building in Brisbane to contrast differences in efficiency requirements of building energy codes within three countries. The results have shown that the GB50189-2015 and ASHRAE 90.1-2016 demonstrated 25.0% and 20.8% annual energy savings respectively compared to the BCA 2016, together with 312,429kg and 259,955kg annual CO2 emissions reduction respectively. In light of this, recommendations for further revision of the Australian building energy code have been provided.
Key concepts: ASHRAE 90.1, HVAC, Building code, Building envelope, Efficient energy use, Architectural engineering, Energy conservation, Engineering