2019•Nepalese Heart JournalOpen access

Echocardiographic assessment of Diastolic Function in patients with Atrial Fibrillation

Ajay Adhikaree, Rabi Malla, Ram Kishor Sah, Arun Maskey, Sujeeb Rajbhandari, Deewakar Sharma, Binayak Gautam, Shaneez Najmy

Open full text 7 citations

Abstract

Background and Aims: Echocardiographic assessment of left ventricular diastolic function in patients with atrial fibrillation is a challenge as loss of atrial kick (A wave), beat to beat variability and left atrium enlargement despite normal atrial pressure make usual guideline based estimation difficult and inaccurate. Hence adoption of additional echocardiography parameters are necessary which are tricky and have varied results. Hence the aim of this study was to study various aspects of diastolic function in patients with atrial fibrillation. Methods: It was a hospital based prospective cross-sectional observational study conducted at cardiology unit, National Academy of Medical Sciences, Kathmandu and Shahid Gangalal National Heart Center, Kathmandu from 1st July 2018 to 30th June 2019. Results: Total of 92 patients were studied. About one third (34.8%) had diastolic dysfunction. Ratio of E/e’(14.65 ± 2.21 Vs 7.66 ± 1.18) , E/Vp (1.57 ± 0.14 Vs 1.20 ± 0.11), isovolumetric relaxation time (53.06 ± 13.82ms Vs 89.33 ± 9.88ms) and deceleration time of pulmonary venous diastolic wave (203.09 ± 26.13ms Vs 292.25 ± 36.32ms) were significantly different in patients with diastolic dysfunction compared to patients without diastolic dysfunction with sensitivity of 90.6%, 84.4%, 81.2% and 78.1% respectively. Conclusion: Diastolic dysfunction is a common entity in patients with atrial fibrillation. Echocardiography parameters like E/e’ ratio, isovolumetric relaxation time, E/Vp ratio and deceleration time of diastolic pulmonary wave were highly sensitive in detection of diastolic dysfunction.

Open-access reader

About this research paper

What this paper is about

Background and Aims: Echocardiographic assessment of left ventricular diastolic function in patients with atrial fibrillation is a challenge as loss of atrial kick (A wave), beat to beat variability and left atrium enlargement despite normal atrial pressure make usual guideline based estimation difficult and inaccurate. Hence adoption of additional echocardiography parameters are necessary which are tricky and have varied results. Hence the aim of this study was to study various aspects of diastolic function in patients with atrial fibrillation. Methods: It was a hospital based prospective cross-sectional observational study conducted at cardiology unit, National Academy of Medical Sciences, Kathmandu and Shahid Gangalal National Heart Center, Kathmandu from 1st July 2018 to 30th June 2019. Results: Total of 92 patients were studied. About one third (34.8%) had diastolic dysfunction. Ratio of E/e’(14.65 ± 2.21 Vs 7.66 ± 1.18) , E/Vp (1.57 ± 0.14 Vs 1.20 ± 0.11), isovolumetric relaxation time (53.06 ± 13.82ms Vs 89.33 ± 9.88ms) and deceleration time of pulmonary venous diastolic wave (203.09 ± 26.13ms Vs 292.25 ± 36.32ms) were significantly different in patients with diastolic dysfunction compared to patients without diastolic dysfunction with sensitivity of 90.6%, 84.4%, 81.2% and 78.1% respectively. Conclusion: Diastolic dysfunction is a common entity in patients with atrial fibrillation. Echocardiography parameters like E/e’ ratio, isovolumetric relaxation time, E/Vp ratio and deceleration time of diastolic pulmonary wave were highly sensitive in detection of diastolic dysfunction.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background and Aims: Echocardiographic assessment of left ventricular diastolic function in patients with atrial fibrillation is a challenge as loss of atrial kick (A wave), beat to beat variability and left atrium enlargement despite normal atrial pressure make usual guideline based estimation difficult and inaccurate. Hence adoption of additional echocardiography parameters are necessary which are tricky and have varied results. Hence the aim of this study was to study various aspects of diastolic function in patients with atrial fibrillation. Methods: It was a hospital based prospective cross-sectional observational study conducted at cardiology unit, National Academy of Medical Sciences, Kathmandu and Shahid Gangalal National Heart Center, Kathmandu from 1st July 2018 to 30th June 2019. Results: Total of 92 patients were studied. About one third (34.8%) had diastolic dysfunction. Ratio of E/e’(14.65 ± 2.21 Vs 7.66 ± 1.18) , E/Vp (1.57 ± 0.14 Vs 1.20 ± 0.11), isovolumetric relaxation time (53.06 ± 13.82ms Vs 89.33 ± 9.88ms) and deceleration time of pulmonary venous diastolic wave (203.09 ± 26.13ms Vs 292.25 ± 36.32ms) were significantly different in patients with diastolic dysfunction compared to patients without diastolic dysfunction with sensitivity of 90.6%, 84.4%, 81.2% and 78.1% respectively. Conclusion: Diastolic dysfunction is a common entity in patients with atrial fibrillation. Echocardiography parameters like E/e’ ratio, isovolumetric relaxation time, E/Vp ratio and deceleration time of diastolic pulmonary wave were highly sensitive in detection of diastolic dysfunction.

Key concepts: Medicine, Isovolumetric contraction, Diastole, Cardiology, Internal medicine, Atrial fibrillation, Diastolic function, Doppler echocardiography

Related papers

Back to paper searchBrowse research topicsOriginal source
Echocardiographic assessment of Diastolic Function in patients with Atrial Fibrillation — Research Paper | ScholarLens