2019Proceedings of the Human Factors and Ergonomics Society Annual MeetingRequires access

Effects of Patient Turning Devices on Muscular Demands of Caregivers

Jaejin Hwang, Hemateja Ari, Megha Matoo, Jie Chen, Jeong Ho Kim

Open publisher page 7 citations

Abstract

This study evaluated the efficacy of commercially-available patient turning devices (draw sheet, friction-reducing turning sheet, air-assisted lateral transfer device, and air-assisted turning device) in reducing muscular demands of caregivers. A repeated-measures laboratory study with 10 experienced caregivers (8 females and 2 males) was conducted to measure the muscle activity in the upper extremities (biceps, triceps, anterior deltoid, middle deltoid, and upper trapezius) and low back (erector spinae) during standardized patient turning tasks. The results showed that the muscle activities in biceps, triceps, and erector spinae were significantly different by transfer device ( p’s < 0.01). The air-assisted turning device showed the significant reduction (21 to 44%) in muscle activities of all muscles except anterior deltoid compared to the conventional manual turning without assistive device (rotating a patient onto caregivers’ sides by pulling the knee and shoulder of the patient). These findings suggest that the air-assisted turning device can be an effective engineering control to reduce the muscular demands in the upper extremities and low back among caregivers.

About this research paper

What this paper is about

This study evaluated the efficacy of commercially-available patient turning devices (draw sheet, friction-reducing turning sheet, air-assisted lateral transfer device, and air-assisted turning device) in reducing muscular demands of caregivers. A repeated-measures laboratory study with 10 experienced caregivers (8 females and 2 males) was conducted to measure the muscle activity in the upper extremities (biceps, triceps, anterior deltoid, middle deltoid, and upper trapezius) and low back (erector spinae) during standardized patient turning tasks. The results showed that the muscle activities in biceps, triceps, and erector spinae were significantly different by transfer device ( p’s < 0.01). The air-assisted turning device showed the significant reduction (21 to 44%) in muscle activities of all muscles except anterior deltoid compared to the conventional manual turning without assistive device (rotating a patient onto caregivers’ sides by pulling the knee and shoulder of the patient). These findings suggest that the air-assisted turning device can be an effective engineering control to reduce the muscular demands in the upper extremities and low back among caregivers.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study evaluated the efficacy of commercially-available patient turning devices (draw sheet, friction-reducing turning sheet, air-assisted lateral transfer device, and air-assisted turning device) in reducing muscular demands of caregivers. A repeated-measures laboratory study with 10 experienced caregivers (8 females and 2 males) was conducted to measure the muscle activity in the upper extremities (biceps, triceps, anterior deltoid, middle deltoid, and upper trapezius) and low back (erector spinae) during standardized patient turning tasks. The results showed that the muscle activities in biceps, triceps, and erector spinae were significantly different by transfer device ( p’s < 0.01). The air-assisted turning device showed the significant reduction (21 to 44%) in muscle activities of all muscles except anterior deltoid compared to the conventional manual turning without assistive device (rotating a patient onto caregivers’ sides by pulling the knee and shoulder of the patient). These findings suggest that the air-assisted turning device can be an effective engineering control to reduce the muscular demands in the upper extremities and low back among caregivers.

Key concepts: Biceps, Deltoid curve, Deltoid muscle, Medicine, Physical medicine and rehabilitation, Biceps femoris muscle, Electromyography, Physical therapy

Related papers

Back to paper searchBrowse research topicsOriginal source
Effects of Patient Turning Devices on Muscular Demands of Caregivers — Research Paper | ScholarLens