Base isolation is nowadays widely considered as an effective strategy to protect structures subject to seismic excitations. However, it has been shown that, in the case of seismic excitations with high energy content at low frequencies, i.e. a near-fault event or a seismic wave propagating itself through alluvial soil, isolation bearings may undergo gross deformations. Observing that the response of base-isolated (BI) systems is dominated by the first-modal contribution and that Tuned Mass Damping (TMD) is able to reduce the fundamental vibration mode, A benchmark structure in which the non-linear response of isolation devices (elastomeric and friction pendulum) is explicitly considered has been recently defined. By using this model, this paper aims to investigate the non-linear behaviour of the benchmark isolated structure when a mass damping system is applied on the isolation layer, in order to study the effectiveness of this strategy in reducing the seismic response of the isolation layer

About this research paper

What this paper is about

Base isolation is nowadays widely considered as an effective strategy to protect structures subject to seismic excitations. However, it has been shown that, in the case of seismic excitations with high energy content at low frequencies, i.e. a near-fault event or a seismic wave propagating itself through alluvial soil, isolation bearings may undergo gross deformations. Observing that the response of base-isolated (BI) systems is dominated by the first-modal contribution and that Tuned Mass Damping (TMD) is able to reduce the fundamental vibration mode, A benchmark structure in which the non-linear response of isolation devices (elastomeric and friction pendulum) is explicitly considered has been recently defined. By using this model, this paper aims to investigate the non-linear behaviour of the benchmark isolated structure when a mass damping system is applied on the isolation layer, in order to study the effectiveness of this strategy in reducing the seismic response of the isolation layer

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Base isolation is nowadays widely considered as an effective strategy to protect structures subject to seismic excitations. However, it has been shown that, in the case of seismic excitations with high energy content at low frequencies, i.e. a near-fault event or a seismic wave propagating itself through alluvial soil, isolation bearings may undergo gross deformations. Observing that the response of base-isolated (BI) systems is dominated by the first-modal contribution and that Tuned Mass Damping (TMD) is able to reduce the fundamental vibration mode, A benchmark structure in which the non-linear response of isolation devices (elastomeric and friction pendulum) is explicitly considered has been recently defined. By using this model, this paper aims to investigate the non-linear behaviour of the benchmark isolated structure when a mass damping system is applied on the isolation layer, in order to study the effectiveness of this strategy in reducing the seismic response of the isolation layer

Key concepts: Base isolation, Earthquake resistance, Structural engineering, Damper, Isolation (microbiology), Base (topology), Resistance (ecology), Engineering