THERMAL STABILITY OF HYDROCARBON FUELS
G. D. Kittredge, W. L. Streets, REX RATCHFORD
Abstract
G. D. Kittredge, W. L. Streets, REX RATCHFORD
Abstract
Abstract : Research was conducted to: (1) develop a small scale jet fuel thermal stability tester capable of operation at fuel temperatures from 300 to 650 F with samples 1 qt or less in size, and (2) study the effects of storage on thermal stability performance of JP-6 grade jet fuels and establish causes (in terms of environmental factors and fuel composition) for any adverse results observed. Three potentially useful techniques were produced: (1) a recirculating-flow dynamic method measuring deposit insulating effects around a heated surface which requires 1000 ml fuel samples, (2) a static method measuring deposit insulating effects around a heated nickel wire which requires 150 ml fuel samples, and (=0 a static method based on ch nges in fuel light transmission characteristics after heating which requires only 5-ml fuel samples. The JP-6 storage stability invesigation (1 yr) showed that 3 out of 5 test fuels did deteriorate significantly after 26 wk at 110 F in terms of CFR fuel Coker rating, while a fourth fuel showed evidence of deterioration in one container only which is attributed to solids contamination.
OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Abstract : Research was conducted to: (1) develop a small scale jet fuel thermal stability tester capable of operation at fuel temperatures from 300 to 650 F with samples 1 qt or less in size, and (2) study the effects of storage on thermal stability performance of JP-6 grade jet fuels and establish causes (in terms of environmental factors and fuel composition) for any adverse results observed. Three potentially useful techniques were produced: (1) a recirculating-flow dynamic method measuring deposit insulating effects around a heated surface which requires 1000 ml fuel samples, (2) a static method measuring deposit insulating effects around a heated nickel wire which requires 150 ml fuel samples, and (=0 a static method based on ch nges in fuel light transmission characteristics after heating which requires only 5-ml fuel samples. The JP-6 storage stability invesigation (1 yr) showed that 3 out of 5 test fuels did deteriorate significantly after 26 wk at 110 F in terms of CFR fuel Coker rating, while a fourth fuel showed evidence of deterioration in one container only which is attributed to solids contamination.
Key concepts: Hydrocarbon, Environmental science, Petroleum engineering, Stability (learning theory), Chemistry, Geology, Organic chemistry, Computer science