2019Journal of Clinical MedicineOpen access

Complications after Chest Tube Removal and Reinterventions in Patients with Digital Drainage Systems

Yi-Ying Lee, Po‐Kuei Hsu, Chien‐Sheng Huang, Yu–Chung Wu, Han‐Shui Hsu

Open full text 15 citations

Abstract

INTRODUCTION: Digital thoracic drainage systems are a new technology in minimally invasive thoracic surgery. However, the criteria for chest tube removal in digital thoracic drainage systems have never been evaluated. We aim to investigate the incidence and predictive factors of complications and reinterventions after drainage tube removal in patients with a digital drainage system. METHOD: Patients who received lung resection surgery and had their chest drainage tubes connected with a digital drainage system were retrospectively reviewed. RESULTS: A total of 497 patients were monitored with digital drainage systems after lung resection surgery. A total of 175 (35.2%) patients had air leak-related complications after drainage tube removals, whereas 25 patients (5.0%) required reintervention. We identified that chest drainage duration of five days was an optimal cut-off value in predicting air leak-related complications and reinterventions. In multiple logistic regression analysis, previous chest surgery history; small size (16 Fr.) drainage tubes; the presence of initial air leaks, defined as air leaks recorded by the digital drainage system immediately after operation; and duration of chest drainage ≥5 days were independent factors of air leak-related complications, whereas the presence of initial air leaks and duration of chest drainage ≥5 days were independent predictive factors of reintervention after drainage tube removal. CONCLUSION: Air leak-related complications and reinterventions after drainage tube removals happened in 35.2% and 5.0% of patients with digital thoracic drainage systems. The management of chest drainage tubes in patients with predictive factors, i.e., the presence of initial air leaks and duration of chest drainage of more than five days, should be treated with caution.

Open-access reader

About this research paper

What this paper is about

INTRODUCTION: Digital thoracic drainage systems are a new technology in minimally invasive thoracic surgery. However, the criteria for chest tube removal in digital thoracic drainage systems have never been evaluated. We aim to investigate the incidence and predictive factors of complications and reinterventions after drainage tube removal in patients with a digital drainage system. METHOD: Patients who received lung resection surgery and had their chest drainage tubes connected with a digital drainage system were retrospectively reviewed. RESULTS: A total of 497 patients were monitored with digital drainage systems after lung resection surgery. A total of 175 (35.2%) patients had air leak-related complications after drainage tube removals, whereas 25 patients (5.0%) required reintervention. We identified that chest drainage duration of five days was an optimal cut-off value in predicting air leak-related complications and reinterventions. In multiple logistic regression analysis, previous chest surgery history; small size (16 Fr.) drainage tubes; the presence of initial air leaks, defined as air leaks recorded by the digital drainage system immediately after operation; and duration of chest drainage ≥5 days were independent factors of air leak-related complications, whereas the presence of initial air leaks and duration of chest drainage ≥5 days were independent predictive factors of reintervention after drainage tube removal. CONCLUSION: Air leak-related complications and reinterventions after drainage tube removals happened in 35.2% and 5.0% of patients with digital thoracic drainage systems. The management of chest drainage tubes in patients with predictive factors, i.e., the presence of initial air leaks and duration of chest drainage of more than five days, should be treated with caution.

Why it matters

OpenAlex reports 15 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

INTRODUCTION: Digital thoracic drainage systems are a new technology in minimally invasive thoracic surgery. However, the criteria for chest tube removal in digital thoracic drainage systems have never been evaluated. We aim to investigate the incidence and predictive factors of complications and reinterventions after drainage tube removal in patients with a digital drainage system. METHOD: Patients who received lung resection surgery and had their chest drainage tubes connected with a digital drainage system were retrospectively reviewed. RESULTS: A total of 497 patients were monitored with digital drainage systems after lung resection surgery. A total of 175 (35.2%) patients had air leak-related complications after drainage tube removals, whereas 25 patients (5.0%) required reintervention. We identified that chest drainage duration of five days was an optimal cut-off value in predicting air leak-related complications and reinterventions. In multiple logistic regression analysis, previous chest surgery history; small size (16 Fr.) drainage tubes; the presence of initial air leaks, defined as air leaks recorded by the digital drainage system immediately after operation; and duration of chest drainage ≥5 days were independent factors of air leak-related complications, whereas the presence of initial air leaks and duration of chest drainage ≥5 days were independent predictive factors of reintervention after drainage tube removal. CONCLUSION: Air leak-related complications and reinterventions after drainage tube removals happened in 35.2% and 5.0% of patients with digital thoracic drainage systems. The management of chest drainage tubes in patients with predictive factors, i.e., the presence of initial air leaks and duration of chest drainage of more than five days, should be treated with caution.

Key concepts: Medicine, Tube (container), Chest tube, Drainage, Surgery, Radiology, Waste management, Pneumothorax

Related papers

Back to paper searchBrowse research topicsOriginal source
Complications after Chest Tube Removal and Reinterventions in Patients with Digital Drainage Systems — Research Paper | ScholarLens