Development of a colloidal gold immunoassay for the detection of four eugenol compounds in water
Xinyi Shen, Xiaoling Wu, Liqiang Liu, Hua Kuang
Abstract
Xinyi Shen, Xiaoling Wu, Liqiang Liu, Hua Kuang
Abstract
A monoclonal antibody (mAb), 2C9, selective for four eugenol compounds, was developed based on the eugenol derivatives (Eug-1). The semi-inhibitory concentrations (IC50) of this antibody against eugenol, isoeugenol, methyl eugenol, and methyl isoeugenol were 0.043, 0.302, 0.016, and 0.082 μg/mL, respectively, and the detection limits (LOD) were 0.012, 0.070, 0.004 and 0.024 μg/mL. With the exception of isoeugenol, which had cross-reactivity of less than 15%, the cross-reactivity of the other compounds was good, ranging from 52.4% to 269%. In the ic-ELISA recovery test, recovery was between 80% and 94%, indicating that the method was suitable for analysis of eugenol compounds in water. The cut-off values of the immunochromatographic strips for the four compounds in water were 5, 100, 100, and 100 μg/mL, respectively, indicating that the ic-ELISA and immunochromatographic strips we developed can be used to rapidly detect eugenol compounds in water.
OpenAlex reports 28 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A monoclonal antibody (mAb), 2C9, selective for four eugenol compounds, was developed based on the eugenol derivatives (Eug-1). The semi-inhibitory concentrations (IC50) of this antibody against eugenol, isoeugenol, methyl eugenol, and methyl isoeugenol were 0.043, 0.302, 0.016, and 0.082 μg/mL, respectively, and the detection limits (LOD) were 0.012, 0.070, 0.004 and 0.024 μg/mL. With the exception of isoeugenol, which had cross-reactivity of less than 15%, the cross-reactivity of the other compounds was good, ranging from 52.4% to 269%. In the ic-ELISA recovery test, recovery was between 80% and 94%, indicating that the method was suitable for analysis of eugenol compounds in water. The cut-off values of the immunochromatographic strips for the four compounds in water were 5, 100, 100, and 100 μg/mL, respectively, indicating that the ic-ELISA and immunochromatographic strips we developed can be used to rapidly detect eugenol compounds in water.
Key concepts: Isoeugenol, Eugenol, Chemistry, Methyl eugenol, Chromatography, Immunoassay, Detection limit, Colloidal gold