The NPL air kerma primary standard free air chamber for medium energy X-rays: summary of factors

G A Bass, S Duane, M. K. Kelly, J W Manning, D J Maughan, R F Nutbrown, T Sander, D R Shipley

Open publisher page 0 citations

Abstract

The National Physical Laboratory (NPL) air kerma primary standard for x-rays generated at kilovoltages from 40 kV up to 300 kV is a parallel plate, guarded field free-air ionisation chamber that covers the range of x-ray qualities from approximately 1.0 mm Al HVL to 20.0 mm Al HVL for therapy level qualities and from 0.085 mm Cu to 6.2 mm Cu for protection level qualities. The usable air kerma rate range is from about 0.2 mGy min-1 to 90 mGy min-1. This standard has been in use at NPL as the national primary standard since the spring of 1998. This report summarises the factors applicable to the chamber response in order to realise air kerma and calibrate a secondary standard. The associated uncertainties are also presented.

About this research paper

What this paper is about

The National Physical Laboratory (NPL) air kerma primary standard for x-rays generated at kilovoltages from 40 kV up to 300 kV is a parallel plate, guarded field free-air ionisation chamber that covers the range of x-ray qualities from approximately 1.0 mm Al HVL to 20.0 mm Al HVL for therapy level qualities and from 0.085 mm Cu to 6.2 mm Cu for protection level qualities. The usable air kerma rate range is from about 0.2 mGy min-1 to 90 mGy min-1. This standard has been in use at NPL as the national primary standard since the spring of 1998. This report summarises the factors applicable to the chamber response in order to realise air kerma and calibrate a secondary standard. The associated uncertainties are also presented.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The National Physical Laboratory (NPL) air kerma primary standard for x-rays generated at kilovoltages from 40 kV up to 300 kV is a parallel plate, guarded field free-air ionisation chamber that covers the range of x-ray qualities from approximately 1.0 mm Al HVL to 20.0 mm Al HVL for therapy level qualities and from 0.085 mm Cu to 6.2 mm Cu for protection level qualities. The usable air kerma rate range is from about 0.2 mGy min-1 to 90 mGy min-1. This standard has been in use at NPL as the national primary standard since the spring of 1998. This report summarises the factors applicable to the chamber response in order to realise air kerma and calibrate a secondary standard. The associated uncertainties are also presented.

Key concepts: Kerma, Primary standard, Ionization chamber, National standard, Nuclear engineering, Environmental science, Materials science, Nuclear medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
The NPL air kerma primary standard free air chamber for medium energy X-rays: summary of factors — Research Paper | ScholarLens