2019•Journal of The Electrochemical SocietyOpen access

Electrochemiluminescence Aptasensor for Profenofos Detection Based on Silver Nanoparticles Enhanced Luminol Luminescence System

Huimin Liu, Shuting Cheng, Xiaojie Shi, Hui Zhang, Qingxue Zhao, Haowei Dong, Yemin Guo, Xia Sun

Open full text 24 citations

Abstract

In this work, an electrochemiluminescence (ECL) aptasensor based on silver nanoparticles (AgNPs) for detection of profenofos was presented. The aptasensor was based on the affinity of the aptamer (Apt) with the target profenofos. When the Apt contacted with the profenofos, the ECL detection signals were weakened, indicating the successful construction of the aptasensor. In order to improve the aptasensor performance, the platinum electrode (PE) was modified by AgNPs due to their good conductivity and catalytic property. Meanwhile luminol-hydrogen peroxide was selected as a luminescence system. Through the standard curve experiment and specificity experiment, it was proved that the sensor had the advantages of low detection limit and good specificity. Under the optimum conditions, the aptasensor had a good linear response to profenofos from 0.5 μg/mL to 100 μg/mL (1.34 μM to 267.6 μM ), with a low detection limit of 0.13 ng/mL and a correlation coefficient (R²) of 0.9903. The aptasensor was also successfully applied for detection of profenofos in real vegetables. Because the developed aptasensor had the following advantages of simple preparation, good stability, high selectivity and sensitivity, it would show great potential for other small molecule contamination detection.

Open-access reader

About this research paper

What this paper is about

In this work, an electrochemiluminescence (ECL) aptasensor based on silver nanoparticles (AgNPs) for detection of profenofos was presented. The aptasensor was based on the affinity of the aptamer (Apt) with the target profenofos. When the Apt contacted with the profenofos, the ECL detection signals were weakened, indicating the successful construction of the aptasensor. In order to improve the aptasensor performance, the platinum electrode (PE) was modified by AgNPs due to their good conductivity and catalytic property. Meanwhile luminol-hydrogen peroxide was selected as a luminescence system. Through the standard curve experiment and specificity experiment, it was proved that the sensor had the advantages of low detection limit and good specificity. Under the optimum conditions, the aptasensor had a good linear response to profenofos from 0.5 μg/mL to 100 μg/mL (1.34 μM to 267.6 μM ), with a low detection limit of 0.13 ng/mL and a correlation coefficient (R²) of 0.9903. The aptasensor was also successfully applied for detection of profenofos in real vegetables. Because the developed aptasensor had the following advantages of simple preparation, good stability, high selectivity and sensitivity, it would show great potential for other small molecule contamination detection.

Why it matters

OpenAlex reports 24 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this work, an electrochemiluminescence (ECL) aptasensor based on silver nanoparticles (AgNPs) for detection of profenofos was presented. The aptasensor was based on the affinity of the aptamer (Apt) with the target profenofos. When the Apt contacted with the profenofos, the ECL detection signals were weakened, indicating the successful construction of the aptasensor. In order to improve the aptasensor performance, the platinum electrode (PE) was modified by AgNPs due to their good conductivity and catalytic property. Meanwhile luminol-hydrogen peroxide was selected as a luminescence system. Through the standard curve experiment and specificity experiment, it was proved that the sensor had the advantages of low detection limit and good specificity. Under the optimum conditions, the aptasensor had a good linear response to profenofos from 0.5 μg/mL to 100 μg/mL (1.34 μM to 267.6 μM ), with a low detection limit of 0.13 ng/mL and a correlation coefficient (R²) of 0.9903. The aptasensor was also successfully applied for detection of profenofos in real vegetables. Because the developed aptasensor had the following advantages of simple preparation, good stability, high selectivity and sensitivity, it would show great potential for other small molecule contamination detection.

Key concepts: Electrochemiluminescence, Detection limit, Aptamer, Luminol, Chemiluminescence, Luminescence, Chemistry, Hydrogen peroxide

Related papers

Back to paper searchBrowse research topicsOriginal source
Electrochemiluminescence Aptasensor for Profenofos Detection Based on Silver Nanoparticles Enhanced Luminol Luminescence System — Research Paper | ScholarLens