2019•International Journal of Molecular SciencesOpen access

Variable Smear Layer and Adhesive Application: The Pursuit of Clinical Relevance in Bond Strength Testing

Abu Faem Mohammad Almas Chowdhury, Rafiqul Islam, Arefin Alam, Mariko Matsumoto, Mônica Yamauti, Ricardo M. Carvalho, Hidehiko Sano

Open full text 32 citations

Abstract

The removal or modification of smear layers that cover the dentin is critical to allow the penetration of adhesive molecules and to ensure a strong bond between resin and dentin. Aiming to establish a model for clinically-relevant dentin-bond testing, we evaluated the effects of smear layers created by abrasives having similar coarseness (180-grit SiC paper; fine-grit diamond bur) and application modes (single application; double application) on the microtensile bond strengths (µTBS) of two currently available universal adhesives (G-Premio Bond; Scotchbond Universal Adhesive) and a two-step self-etch adhesive (Clearfil Megabond 2). Sixty extracted human third molars were used for the μTBS test. Data were analyzed by three-way ANOVA and Tukey’s test (α = 0.05). Fracture modes were determined using stereomicroscopy. An additional 24 third molars were prepared for observation of the resin–dentin interface by TEM and adhesive-smear layer interaction by SEM. μTBS was significantly affected by the adhesives and their application modes (p < 0.001), implying that the double application of universal adhesives should be recommended to improve their performance. The effect of smear layers was not significant (p > 0.05), indicating that 180-grit SiC papers could be used to prepare dentin as a substitute for fine-grit diamond burs for dentin-bond testing in laboratory settings.

Open-access reader

About this research paper

What this paper is about

The removal or modification of smear layers that cover the dentin is critical to allow the penetration of adhesive molecules and to ensure a strong bond between resin and dentin. Aiming to establish a model for clinically-relevant dentin-bond testing, we evaluated the effects of smear layers created by abrasives having similar coarseness (180-grit SiC paper; fine-grit diamond bur) and application modes (single application; double application) on the microtensile bond strengths (µTBS) of two currently available universal adhesives (G-Premio Bond; Scotchbond Universal Adhesive) and a two-step self-etch adhesive (Clearfil Megabond 2). Sixty extracted human third molars were used for the μTBS test. Data were analyzed by three-way ANOVA and Tukey’s test (α = 0.05). Fracture modes were determined using stereomicroscopy. An additional 24 third molars were prepared for observation of the resin–dentin interface by TEM and adhesive-smear layer interaction by SEM. μTBS was significantly affected by the adhesives and their application modes (p < 0.001), implying that the double application of universal adhesives should be recommended to improve their performance. The effect of smear layers was not significant (p > 0.05), indicating that 180-grit SiC papers could be used to prepare dentin as a substitute for fine-grit diamond burs for dentin-bond testing in laboratory settings.

Why it matters

OpenAlex reports 32 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The removal or modification of smear layers that cover the dentin is critical to allow the penetration of adhesive molecules and to ensure a strong bond between resin and dentin. Aiming to establish a model for clinically-relevant dentin-bond testing, we evaluated the effects of smear layers created by abrasives having similar coarseness (180-grit SiC paper; fine-grit diamond bur) and application modes (single application; double application) on the microtensile bond strengths (µTBS) of two currently available universal adhesives (G-Premio Bond; Scotchbond Universal Adhesive) and a two-step self-etch adhesive (Clearfil Megabond 2). Sixty extracted human third molars were used for the μTBS test. Data were analyzed by three-way ANOVA and Tukey’s test (α = 0.05). Fracture modes were determined using stereomicroscopy. An additional 24 third molars were prepared for observation of the resin–dentin interface by TEM and adhesive-smear layer interaction by SEM. μTBS was significantly affected by the adhesives and their application modes (p < 0.001), implying that the double application of universal adhesives should be recommended to improve their performance. The effect of smear layers was not significant (p > 0.05), indicating that 180-grit SiC papers could be used to prepare dentin as a substitute for fine-grit diamond burs for dentin-bond testing in laboratory settings.

Key concepts: Adhesive, Dentin, Materials science, Bond strength, Molar, Smear layer, Composite material, Universal testing machine

Related papers

Back to paper searchBrowse research topicsOriginal source
Variable Smear Layer and Adhesive Application: The Pursuit of Clinical Relevance in Bond Strength Testing — Research Paper | ScholarLens