2019•Journal of Orthopaedic TraumaRequires access

Precontoured Quadrilateral Surface Acetabular Plate Fixation Demonstrates Increased Stability When Compared With Pelvic Reconstruction Plates: A Biomechanical Study

Weston K. Ryan, Nicholas A. Alfonso, Todd H. Baldini, Pam Kumparatana, Michael J. Reiter, Christopher D. Joyce, Wei Chen, Yingzhe Zhang, Cyril P. Mauffrey

Open publisher page 9 citations

Abstract

OBJECTIVE: To compare the stability of 3 fixation strategies for a transverse acetabular fracture: a reconstruction plate with anterior and posterior column screws (group A); an infrapectineal precontoured quadrilateral surface buttress (iPQSB) plate alone (group B); and an anterior column lag-screw and iPQSB plate (group C). METHODS: A transverse acetabular fracture was created in 18 synthetic hemipelvises. Six were fixed by each of the 3 methods described. Specimens underwent cyclic axial compressive loading to 1700N for 42,000 cycles while anterior and posterior column displacements were measured, followed 4800N for 50 cycles. Displacement and stiffness data were analyzed with analysis of variance and Tukey HSD. A Cox proportional hazards regression model was used to determine survival rate. P values < 0.05 were considered significant. RESULTS: Group C had significantly less posterior column displacement (0.16 ± 0.06 mm) compared with group B (0.38 ± 0.37 mm, P < 0.0001) and group A (0.38 ± 0.37 mm, P < 0.0001). In addition, group A had significantly more anterior column displacement (0.28 ± 0.11 mm) than group B (0.22 ± 0.14 mm, P = 0.0310) and group C (0.18 ± 0.09 mm, P = 0.0001). Group C was 10.5% stiffer than group A (P = 0.0037). Group B had a 7.27x greater rate of failure than group C (95% confidence interval, 1.6-33.2). DISCUSSION AND CONCLUSION: Under anatomical loading, iPQSB plates with anterior column lag-screw fixation demonstrate increased stability in a synthetic bone transverse acetabular fracture model. Based on our data, we support additional evaluation of early weight-bearing after transverse acetabular fracture fixation in patients with healthy bone when an anterior column screw-iPQSB plate construct is used.

About this research paper

What this paper is about

OBJECTIVE: To compare the stability of 3 fixation strategies for a transverse acetabular fracture: a reconstruction plate with anterior and posterior column screws (group A); an infrapectineal precontoured quadrilateral surface buttress (iPQSB) plate alone (group B); and an anterior column lag-screw and iPQSB plate (group C). METHODS: A transverse acetabular fracture was created in 18 synthetic hemipelvises. Six were fixed by each of the 3 methods described. Specimens underwent cyclic axial compressive loading to 1700N for 42,000 cycles while anterior and posterior column displacements were measured, followed 4800N for 50 cycles. Displacement and stiffness data were analyzed with analysis of variance and Tukey HSD. A Cox proportional hazards regression model was used to determine survival rate. P values < 0.05 were considered significant. RESULTS: Group C had significantly less posterior column displacement (0.16 ± 0.06 mm) compared with group B (0.38 ± 0.37 mm, P < 0.0001) and group A (0.38 ± 0.37 mm, P < 0.0001). In addition, group A had significantly more anterior column displacement (0.28 ± 0.11 mm) than group B (0.22 ± 0.14 mm, P = 0.0310) and group C (0.18 ± 0.09 mm, P = 0.0001). Group C was 10.5% stiffer than group A (P = 0.0037). Group B had a 7.27x greater rate of failure than group C (95% confidence interval, 1.6-33.2). DISCUSSION AND CONCLUSION: Under anatomical loading, iPQSB plates with anterior column lag-screw fixation demonstrate increased stability in a synthetic bone transverse acetabular fracture model. Based on our data, we support additional evaluation of early weight-bearing after transverse acetabular fracture fixation in patients with healthy bone when an anterior column screw-iPQSB plate construct is used.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To compare the stability of 3 fixation strategies for a transverse acetabular fracture: a reconstruction plate with anterior and posterior column screws (group A); an infrapectineal precontoured quadrilateral surface buttress (iPQSB) plate alone (group B); and an anterior column lag-screw and iPQSB plate (group C). METHODS: A transverse acetabular fracture was created in 18 synthetic hemipelvises. Six were fixed by each of the 3 methods described. Specimens underwent cyclic axial compressive loading to 1700N for 42,000 cycles while anterior and posterior column displacements were measured, followed 4800N for 50 cycles. Displacement and stiffness data were analyzed with analysis of variance and Tukey HSD. A Cox proportional hazards regression model was used to determine survival rate. P values < 0.05 were considered significant. RESULTS: Group C had significantly less posterior column displacement (0.16 ± 0.06 mm) compared with group B (0.38 ± 0.37 mm, P < 0.0001) and group A (0.38 ± 0.37 mm, P < 0.0001). In addition, group A had significantly more anterior column displacement (0.28 ± 0.11 mm) than group B (0.22 ± 0.14 mm, P = 0.0310) and group C (0.18 ± 0.09 mm, P = 0.0001). Group C was 10.5% stiffer than group A (P = 0.0037). Group B had a 7.27x greater rate of failure than group C (95% confidence interval, 1.6-33.2). DISCUSSION AND CONCLUSION: Under anatomical loading, iPQSB plates with anterior column lag-screw fixation demonstrate increased stability in a synthetic bone transverse acetabular fracture model. Based on our data, we support additional evaluation of early weight-bearing after transverse acetabular fracture fixation in patients with healthy bone when an anterior column screw-iPQSB plate construct is used.

Key concepts: Medicine, Posterior column, Acetabulum, Acetabular fracture, Fixation (population genetics), Displacement (psychology), Transverse plane, Orthodontics

Related papers

Back to paper searchBrowse research topicsOriginal source
Precontoured Quadrilateral Surface Acetabular Plate Fixation Demonstrates Increased Stability When Compared With Pelvic Reconstruction Plates: A Biomechanical Study — Research Paper | ScholarLens