2019Russian Journal of Applied ChemistryRequires access

Study of the Influence Exerted by Addition of Coker Gas Oil to Straight-Run Gas Oil on the Process of Hydrotreating in the Presence of CoMo/Al2O3 Catalyst

П. В. Александров, G. A. Bukhtiyarova, С. И. Решетников

Open publisher page 6 citations

Abstract

Behavior of the CoMo/Al 2 O 3 catalyst was experimentally studied in the course of hydrotreating of a straight-run gas oil with high content of sulfur (>2 wt %) and its mixture (up to 30 wt %) with light coker gas oil in the temperature range 335–365°C and liquid hour space velocity of feedstock deliver of 0.8–2.5 h −1 . It was shown that addition of gas oil to the straight-run gas oil in hydrotreating under the conditions corresponding to the working conditions of the existing domestic hydrotreating installations [L-24-5, L-24-6, L(Ch)-24-7] has oppositely directed effects, depending on temperature and feedstock delivery rate. For example, the additives lead in the temperature range 335–350°C to an increase in the content of sulfur in hydrotreating products. At a temperature of 365°C, better sulfur-related parameters are reached in processing of feedstocks containing light coker gas oil. The observed dependences are accounted for as follows: the dilution of the straight-run gas oil by addition of light coker gas oil leads to a decrease in the content of difficulty converted sulfur-containing compounds, but makes larger the content of nitrogen-containing compounds inhibitors of the hydrodesulfurization reaction, the influence of which on the reaction rate becomes weaker with increasing temperature.

About this research paper

What this paper is about

Behavior of the CoMo/Al 2 O 3 catalyst was experimentally studied in the course of hydrotreating of a straight-run gas oil with high content of sulfur (>2 wt %) and its mixture (up to 30 wt %) with light coker gas oil in the temperature range 335–365°C and liquid hour space velocity of feedstock deliver of 0.8–2.5 h −1 . It was shown that addition of gas oil to the straight-run gas oil in hydrotreating under the conditions corresponding to the working conditions of the existing domestic hydrotreating installations [L-24-5, L-24-6, L(Ch)-24-7] has oppositely directed effects, depending on temperature and feedstock delivery rate. For example, the additives lead in the temperature range 335–350°C to an increase in the content of sulfur in hydrotreating products. At a temperature of 365°C, better sulfur-related parameters are reached in processing of feedstocks containing light coker gas oil. The observed dependences are accounted for as follows: the dilution of the straight-run gas oil by addition of light coker gas oil leads to a decrease in the content of difficulty converted sulfur-containing compounds, but makes larger the content of nitrogen-containing compounds inhibitors of the hydrodesulfurization reaction, the influence of which on the reaction rate becomes weaker with increasing temperature.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Behavior of the CoMo/Al 2 O 3 catalyst was experimentally studied in the course of hydrotreating of a straight-run gas oil with high content of sulfur (>2 wt %) and its mixture (up to 30 wt %) with light coker gas oil in the temperature range 335–365°C and liquid hour space velocity of feedstock deliver of 0.8–2.5 h −1 . It was shown that addition of gas oil to the straight-run gas oil in hydrotreating under the conditions corresponding to the working conditions of the existing domestic hydrotreating installations [L-24-5, L-24-6, L(Ch)-24-7] has oppositely directed effects, depending on temperature and feedstock delivery rate. For example, the additives lead in the temperature range 335–350°C to an increase in the content of sulfur in hydrotreating products. At a temperature of 365°C, better sulfur-related parameters are reached in processing of feedstocks containing light coker gas oil. The observed dependences are accounted for as follows: the dilution of the straight-run gas oil by addition of light coker gas oil leads to a decrease in the content of difficulty converted sulfur-containing compounds, but makes larger the content of nitrogen-containing compounds inhibitors of the hydrodesulfurization reaction, the influence of which on the reaction rate becomes weaker with increasing temperature.

Key concepts: Hydrodesulfurization, Coker unit, Chemistry, Fuel oil, Sulfur, Catalysis, Hydrodenitrogenation, Space velocity

Related papers

Back to paper searchBrowse research topicsOriginal source
Study of the Influence Exerted by Addition of Coker Gas Oil to Straight-Run Gas Oil on the Process of Hydrotreating in the Presence of CoMo/Al2O3 Catalyst — Research Paper | ScholarLens