2019University of Thi-Qar JournalOpen access

EXPERIMENTAL STUDY FOR THE INTERACTION CURVES OF CFST COLUMNS SUBJECTED TO A STATIC CENTRIC OR ECCENTRIC LOADS

Author information unavailable

Open full text 0 citations

Abstract

An experimental study on composite columns of square and circular steel hollow sections filled with normal concrete has been held in this paper.The concrete used in this study have two different compressive strength with mixing ratios of (1:2:4) and (1:1.5:3); the compressive strength of concrete were (22.9 MPa) and (31.8 MPa) respectively.Square steel hollow sections of (7.5×7.5 cm) and 2 mm thickness used with a yield stress of (352 MPa) while the circular hollow sections have (7.5 cm) diameter and 2 mm thickness with a yield strength of (327 MPa).Samples tested under the effect of concentric and eccentric axial loads with one case in which the column tested horizontally as a beam to evaluate the maximum bending resistance.The interaction curves for both shapes of columns and for two different concrete compressive strength are presented with a simple analysis for the pattern of failure in columns for each case of loading and for each type.The results show that the increase in compression strength of concrete provides more capacity for the composite columns in axial loading more than bending due to the confinement, and the failure in columns with square cross-sections are different from those which have circular cross-sectional area.

Open-access reader

About this research paper

What this paper is about

An experimental study on composite columns of square and circular steel hollow sections filled with normal concrete has been held in this paper.The concrete used in this study have two different compressive strength with mixing ratios of (1:2:4) and (1:1.5:3); the compressive strength of concrete were (22.9 MPa) and (31.8 MPa) respectively.Square steel hollow sections of (7.5×7.5 cm) and 2 mm thickness used with a yield stress of (352 MPa) while the circular hollow sections have (7.5 cm) diameter and 2 mm thickness with a yield strength of (327 MPa).Samples tested under the effect of concentric and eccentric axial loads with one case in which the column tested horizontally as a beam to evaluate the maximum bending resistance.The interaction curves for both shapes of columns and for two different concrete compressive strength are presented with a simple analysis for the pattern of failure in columns for each case of loading and for each type.The results show that the increase in compression strength of concrete provides more capacity for the composite columns in axial loading more than bending due to the confinement, and the failure in columns with square cross-sections are different from those which have circular cross-sectional area.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An experimental study on composite columns of square and circular steel hollow sections filled with normal concrete has been held in this paper.The concrete used in this study have two different compressive strength with mixing ratios of (1:2:4) and (1:1.5:3); the compressive strength of concrete were (22.9 MPa) and (31.8 MPa) respectively.Square steel hollow sections of (7.5×7.5 cm) and 2 mm thickness used with a yield stress of (352 MPa) while the circular hollow sections have (7.5 cm) diameter and 2 mm thickness with a yield strength of (327 MPa).Samples tested under the effect of concentric and eccentric axial loads with one case in which the column tested horizontally as a beam to evaluate the maximum bending resistance.The interaction curves for both shapes of columns and for two different concrete compressive strength are presented with a simple analysis for the pattern of failure in columns for each case of loading and for each type.The results show that the increase in compression strength of concrete provides more capacity for the composite columns in axial loading more than bending due to the confinement, and the failure in columns with square cross-sections are different from those which have circular cross-sectional area.

Key concepts: Eccentric, Structural engineering, Physics, Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
EXPERIMENTAL STUDY FOR THE INTERACTION CURVES OF CFST COLUMNS SUBJECTED TO A STATIC CENTRIC OR ECCENTRIC LOADS — Research Paper | ScholarLens