Design and Validation of a New Programmable Current Source for Electrical Impedance Tomography Applications
Ramesh Kumar, Sharvan Kumar, Amit Sengupta
Abstract
Ramesh Kumar, Sharvan Kumar, Amit Sengupta
Abstract
This paper proposed an advanced digital voltage-controlled multi-frequency based constant current source, which is a wide range of loads and high SNR ratio for Electrical Impedance Tomography (EIT) application. In EIT a constant current source is required for injecting a sinusoidal current pulse to the phantom boundary. The boundary potentials are measured by inserting content current from the phantom boundary according to the variation in frequency and current levels. For studying the wide range of tissue conductivity among different type of subjects (the multi-frequency scanning) is desired in medical Electrical impedance tomography. The proposed Current source, which shows that the simulation has good performance at multi-frequency range with accuracy and stability. In proteus simulation software, the results show that the proposed circuit presents a more stable impedance output and the obtained boundary data at multi-frequency for the validation of the obtained data has been shown using suitable image reconstruction algorithm and is found suitable for image reconstruction much easier.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
This paper proposed an advanced digital voltage-controlled multi-frequency based constant current source, which is a wide range of loads and high SNR ratio for Electrical Impedance Tomography (EIT) application. In EIT a constant current source is required for injecting a sinusoidal current pulse to the phantom boundary. The boundary potentials are measured by inserting content current from the phantom boundary according to the variation in frequency and current levels. For studying the wide range of tissue conductivity among different type of subjects (the multi-frequency scanning) is desired in medical Electrical impedance tomography. The proposed Current source, which shows that the simulation has good performance at multi-frequency range with accuracy and stability. In proteus simulation software, the results show that the proposed circuit presents a more stable impedance output and the obtained boundary data at multi-frequency for the validation of the obtained data has been shown using suitable image reconstruction algorithm and is found suitable for image reconstruction much easier.
Key concepts: Electrical impedance tomography, Imaging phantom, Current source, Electrical impedance, Current (fluid), Voltage, Constant current, Voltage source