2019Burapha Science Journal (วารสารวิทยาศาสตร์บูรพา )Requires access

Determination of Parabens in Cosmetic Samples by Sub-Minute High-Performance Liquid Chromatography Method

Somsak Sirichai, Khajadpai Thipyapong

Open publisher page 0 citations

Abstract

This research was developed to a sub-minute separation method and simultaneous determination of methylparaben, ethylparaben, propylparaben and butylparaben in cosmetic samples by high-performance liquid chromatography coupled with photodiode array detector for simultaneous determination of methylparaben, ethylparaben, propylparaben and butylparaben in cosmetic samples. Parabens were separated on a Chromolith column using gradient elution with acetonitrile and water, the flow rate of 1.3 mL  min -1 and detected at 254 nm.  Under the optimal conditions, the separation was completed in less than 1 min. Calibration curves for standard solution of parabens  were linear over the concentration range of 0.50-10.0 mg L -1 with R 2 greater than 0.999. The limits of detection and limits of quantification of parabens were found between 0.12-0.15 mg L -1 , and 0.40-0.45 mg L -1 , respectively. The accuracy in terms of percent recovery of parabens was in the range of 97.2-102.6. Repeatability and reproducibility of the method were in the range of 1.11-1.50% and 2.30-2.70%, respectively. The development method could be applied to the simultaneous determination of parabens in cosmetic samples. Keywords: high-performance liquid chromatography, sub-minute, paraben, cosmetic

About this research paper

What this paper is about

This research was developed to a sub-minute separation method and simultaneous determination of methylparaben, ethylparaben, propylparaben and butylparaben in cosmetic samples by high-performance liquid chromatography coupled with photodiode array detector for simultaneous determination of methylparaben, ethylparaben, propylparaben and butylparaben in cosmetic samples. Parabens were separated on a Chromolith column using gradient elution with acetonitrile and water, the flow rate of 1.3 mL  min -1 and detected at 254 nm.  Under the optimal conditions, the separation was completed in less than 1 min. Calibration curves for standard solution of parabens  were linear over the concentration range of 0.50-10.0 mg L -1 with R 2 greater than 0.999. The limits of detection and limits of quantification of parabens were found between 0.12-0.15 mg L -1 , and 0.40-0.45 mg L -1 , respectively. The accuracy in terms of percent recovery of parabens was in the range of 97.2-102.6. Repeatability and reproducibility of the method were in the range of 1.11-1.50% and 2.30-2.70%, respectively. The development method could be applied to the simultaneous determination of parabens in cosmetic samples. Keywords: high-performance liquid chromatography, sub-minute, paraben, cosmetic

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This research was developed to a sub-minute separation method and simultaneous determination of methylparaben, ethylparaben, propylparaben and butylparaben in cosmetic samples by high-performance liquid chromatography coupled with photodiode array detector for simultaneous determination of methylparaben, ethylparaben, propylparaben and butylparaben in cosmetic samples. Parabens were separated on a Chromolith column using gradient elution with acetonitrile and water, the flow rate of 1.3 mL  min -1 and detected at 254 nm.  Under the optimal conditions, the separation was completed in less than 1 min. Calibration curves for standard solution of parabens  were linear over the concentration range of 0.50-10.0 mg L -1 with R 2 greater than 0.999. The limits of detection and limits of quantification of parabens were found between 0.12-0.15 mg L -1 , and 0.40-0.45 mg L -1 , respectively. The accuracy in terms of percent recovery of parabens was in the range of 97.2-102.6. Repeatability and reproducibility of the method were in the range of 1.11-1.50% and 2.30-2.70%, respectively. The development method could be applied to the simultaneous determination of parabens in cosmetic samples. Keywords: high-performance liquid chromatography, sub-minute, paraben, cosmetic

Key concepts: Methylparaben, Propylparaben, Paraben, Chromatography, Repeatability, Chemistry, Detection limit, Reproducibility

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Parabens in Cosmetic Samples by Sub-Minute High-Performance Liquid Chromatography Method — Research Paper | ScholarLens