2019Saudi Journal of AnaesthesiaOpen access

Comparative study of fiber-optic guided tracheal intubation through intubating laryngeal mask airway LMA Fastrach™ and i-gel in adult paralyzed patients

Suvidha Sood, Anupriya Saxena, Anil Thakur, Shikha Chahar

Open full text 5 citations

Abstract

BACKGROUND: The i-gel is a novel and innovative supraglottic airway management device used both as an airway rescue device and as a conduit for fiberoptic intubation. In this prospective randomized study, we compared fiberoptic-guided tracheal intubation through the i-gel and LMA Fastrach™ in adult paralyzed patients. MATERIALS AND METHODS: After ethical committee approval and written informed consent, 60 patients of either sex were randomly allocated to either group of supraglottic airway device (SGAD). After successful insertion of the SGAD, the fiberoptic bronchoscope (FOB)-guided tracheal intubation was done through the respective SGAD. The primary objectives were the ease and time taken for fiberoptic-guided intubation in either group. Secondary variables included time taken for successful placement of SGAD, ease of insertion of SGAD, airway seal pressure, ease and time of removal of SGAD, variation in hemodynamic parameters, and complications if any. RESULTS: Time taken for tracheal intubation in LMA Fastrach™ group was 69.53 ± 5.09 s and for the i-gel group it was 72.33 ± 6.73 s. It was seen that it was easy to insert the endotracheal tube (ETT) in 93.3% patients in the LMA Fastrach™ group and 96.7% patients in the i-gel group. Airway seal pressure was higher for the LMA Fastrach™ group. Both the SGADs were comparable in the number of attempts of insertion, ease of insertion, and insertion time. In addition, the hemodynamic variables noted did not show any increase after insertion of SGAD. There was no difficulty encountered in removal of either SGAD. CONCLUSION: I-gel may be a reliable and cost-effective alternative to LMA Fastrach™ for fibreoptic-guided tracheal intubation.

About this research paper

What this paper is about

BACKGROUND: The i-gel is a novel and innovative supraglottic airway management device used both as an airway rescue device and as a conduit for fiberoptic intubation. In this prospective randomized study, we compared fiberoptic-guided tracheal intubation through the i-gel and LMA Fastrach™ in adult paralyzed patients. MATERIALS AND METHODS: After ethical committee approval and written informed consent, 60 patients of either sex were randomly allocated to either group of supraglottic airway device (SGAD). After successful insertion of the SGAD, the fiberoptic bronchoscope (FOB)-guided tracheal intubation was done through the respective SGAD. The primary objectives were the ease and time taken for fiberoptic-guided intubation in either group. Secondary variables included time taken for successful placement of SGAD, ease of insertion of SGAD, airway seal pressure, ease and time of removal of SGAD, variation in hemodynamic parameters, and complications if any. RESULTS: Time taken for tracheal intubation in LMA Fastrach™ group was 69.53 ± 5.09 s and for the i-gel group it was 72.33 ± 6.73 s. It was seen that it was easy to insert the endotracheal tube (ETT) in 93.3% patients in the LMA Fastrach™ group and 96.7% patients in the i-gel group. Airway seal pressure was higher for the LMA Fastrach™ group. Both the SGADs were comparable in the number of attempts of insertion, ease of insertion, and insertion time. In addition, the hemodynamic variables noted did not show any increase after insertion of SGAD. There was no difficulty encountered in removal of either SGAD. CONCLUSION: I-gel may be a reliable and cost-effective alternative to LMA Fastrach™ for fibreoptic-guided tracheal intubation.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: The i-gel is a novel and innovative supraglottic airway management device used both as an airway rescue device and as a conduit for fiberoptic intubation. In this prospective randomized study, we compared fiberoptic-guided tracheal intubation through the i-gel and LMA Fastrach™ in adult paralyzed patients. MATERIALS AND METHODS: After ethical committee approval and written informed consent, 60 patients of either sex were randomly allocated to either group of supraglottic airway device (SGAD). After successful insertion of the SGAD, the fiberoptic bronchoscope (FOB)-guided tracheal intubation was done through the respective SGAD. The primary objectives were the ease and time taken for fiberoptic-guided intubation in either group. Secondary variables included time taken for successful placement of SGAD, ease of insertion of SGAD, airway seal pressure, ease and time of removal of SGAD, variation in hemodynamic parameters, and complications if any. RESULTS: Time taken for tracheal intubation in LMA Fastrach™ group was 69.53 ± 5.09 s and for the i-gel group it was 72.33 ± 6.73 s. It was seen that it was easy to insert the endotracheal tube (ETT) in 93.3% patients in the LMA Fastrach™ group and 96.7% patients in the i-gel group. Airway seal pressure was higher for the LMA Fastrach™ group. Both the SGADs were comparable in the number of attempts of insertion, ease of insertion, and insertion time. In addition, the hemodynamic variables noted did not show any increase after insertion of SGAD. There was no difficulty encountered in removal of either SGAD. CONCLUSION: I-gel may be a reliable and cost-effective alternative to LMA Fastrach™ for fibreoptic-guided tracheal intubation.

Key concepts: Medicine, Insertion time, Intubation, Anesthesia, Mascara, Laryngeal Masks, Airway, Laryngeal mask airway

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparative study of fiber-optic guided tracheal intubation through intubating laryngeal mask airway LMA Fastrach™ and i-gel in adult paralyzed patients — Research Paper | ScholarLens