A comparison of King vision video laryngoscope with CMAC D-blade in obese patients with anticipated difficult airway in tertiary hospital in India – Randomized control study
AnitySingh Dhanyee, Raj Sahajanandan, ArunKumar Gautam
Abstract
AnitySingh Dhanyee, Raj Sahajanandan, ArunKumar Gautam
Abstract
BACKGROUND AND AIMS: This randomized control trial was conducted to compare two video laryngoscopes in obese patients with anticipated difficult airway. Video laryngoscopes have shown to be beneficial in many difficult airway scenarios including obesity. Many studies have shown that even though the glottic view is better, it takes longer to negotiate the endotracheal tube. We proposed to compare CMAC D-blade with King vision-channeled blade for intubating obese patients with anticipated airway difficulty. We hypothesized that channeled scope may be superior as once visualized, tube could be easily negotiated. This would be reflected by time taken for the glottis visualization, time taken for intubation, incidence of complications, and hemodynamic stability. MATERIAL AND METHODS: Sixty-three patients who fulfilled inclusion criteria were enrolled after informed consent. Based on the computer-generated randomization, they were assigned to group 1 (King vision laryngoscope - KVL) and group 2 (CMAC D-blade). All anesthetists who intubated, performed 20 intubations with both video laryngoscopes on manikin before performing the study case. The parameters analyzed were time to visualize the glottis, time to successful intubation, and intubation-related hemodynamic variations and complications. RESULTS: value 0.04). CONCLUSION: There was no statistically significant difference in time to visualize the glottis and intubation between KVL and CMAC D-blade. But there was a high incidence of complications with KVL.
OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
BACKGROUND AND AIMS: This randomized control trial was conducted to compare two video laryngoscopes in obese patients with anticipated difficult airway. Video laryngoscopes have shown to be beneficial in many difficult airway scenarios including obesity. Many studies have shown that even though the glottic view is better, it takes longer to negotiate the endotracheal tube. We proposed to compare CMAC D-blade with King vision-channeled blade for intubating obese patients with anticipated airway difficulty. We hypothesized that channeled scope may be superior as once visualized, tube could be easily negotiated. This would be reflected by time taken for the glottis visualization, time taken for intubation, incidence of complications, and hemodynamic stability. MATERIAL AND METHODS: Sixty-three patients who fulfilled inclusion criteria were enrolled after informed consent. Based on the computer-generated randomization, they were assigned to group 1 (King vision laryngoscope - KVL) and group 2 (CMAC D-blade). All anesthetists who intubated, performed 20 intubations with both video laryngoscopes on manikin before performing the study case. The parameters analyzed were time to visualize the glottis, time to successful intubation, and intubation-related hemodynamic variations and complications. RESULTS: value 0.04). CONCLUSION: There was no statistically significant difference in time to visualize the glottis and intubation between KVL and CMAC D-blade. But there was a high incidence of complications with KVL.
Key concepts: Glottis, Laryngoscopes, Medicine, Video laryngoscope, Intubation, Airway, Anesthesia, Endotracheal tube