BACKGROUND AND AIMS: This randomized control trial was conducted to compare two video laryngoscopes in obese patients with anticipated difficult airway. Video laryngoscopes have shown to be beneficial in many difficult airway scenarios including obesity. Many studies have shown that even though the glottic view is better, it takes longer to negotiate the endotracheal tube. We proposed to compare CMAC D-blade with King vision-channeled blade for intubating obese patients with anticipated airway difficulty. We hypothesized that channeled scope may be superior as once visualized, tube could be easily negotiated. This would be reflected by time taken for the glottis visualization, time taken for intubation, incidence of complications, and hemodynamic stability. MATERIAL AND METHODS: Sixty-three patients who fulfilled inclusion criteria were enrolled after informed consent. Based on the computer-generated randomization, they were assigned to group 1 (King vision laryngoscope - KVL) and group 2 (CMAC D-blade). All anesthetists who intubated, performed 20 intubations with both video laryngoscopes on manikin before performing the study case. The parameters analyzed were time to visualize the glottis, time to successful intubation, and intubation-related hemodynamic variations and complications. RESULTS: value 0.04). CONCLUSION: There was no statistically significant difference in time to visualize the glottis and intubation between KVL and CMAC D-blade. But there was a high incidence of complications with KVL.

About this research paper

What this paper is about

BACKGROUND AND AIMS: This randomized control trial was conducted to compare two video laryngoscopes in obese patients with anticipated difficult airway. Video laryngoscopes have shown to be beneficial in many difficult airway scenarios including obesity. Many studies have shown that even though the glottic view is better, it takes longer to negotiate the endotracheal tube. We proposed to compare CMAC D-blade with King vision-channeled blade for intubating obese patients with anticipated airway difficulty. We hypothesized that channeled scope may be superior as once visualized, tube could be easily negotiated. This would be reflected by time taken for the glottis visualization, time taken for intubation, incidence of complications, and hemodynamic stability. MATERIAL AND METHODS: Sixty-three patients who fulfilled inclusion criteria were enrolled after informed consent. Based on the computer-generated randomization, they were assigned to group 1 (King vision laryngoscope - KVL) and group 2 (CMAC D-blade). All anesthetists who intubated, performed 20 intubations with both video laryngoscopes on manikin before performing the study case. The parameters analyzed were time to visualize the glottis, time to successful intubation, and intubation-related hemodynamic variations and complications. RESULTS: value 0.04). CONCLUSION: There was no statistically significant difference in time to visualize the glottis and intubation between KVL and CMAC D-blade. But there was a high incidence of complications with KVL.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND AND AIMS: This randomized control trial was conducted to compare two video laryngoscopes in obese patients with anticipated difficult airway. Video laryngoscopes have shown to be beneficial in many difficult airway scenarios including obesity. Many studies have shown that even though the glottic view is better, it takes longer to negotiate the endotracheal tube. We proposed to compare CMAC D-blade with King vision-channeled blade for intubating obese patients with anticipated airway difficulty. We hypothesized that channeled scope may be superior as once visualized, tube could be easily negotiated. This would be reflected by time taken for the glottis visualization, time taken for intubation, incidence of complications, and hemodynamic stability. MATERIAL AND METHODS: Sixty-three patients who fulfilled inclusion criteria were enrolled after informed consent. Based on the computer-generated randomization, they were assigned to group 1 (King vision laryngoscope - KVL) and group 2 (CMAC D-blade). All anesthetists who intubated, performed 20 intubations with both video laryngoscopes on manikin before performing the study case. The parameters analyzed were time to visualize the glottis, time to successful intubation, and intubation-related hemodynamic variations and complications. RESULTS: value 0.04). CONCLUSION: There was no statistically significant difference in time to visualize the glottis and intubation between KVL and CMAC D-blade. But there was a high incidence of complications with KVL.