2019Retinal Cases & Brief ReportsRequires access

CLOSURE OF SMALL MACULAR HOLES USING VITRECTOMY SURGERY WITH INTERNAL LIMITING MEMBRANE PEELING WITHOUT THE USE OF INTRAOCULAR GAS TAMPONADE: BROADENING THE UNDERSTANDING OF THE MACULAR HOLE PATHOPHYSIOLOGY

David R. Lally, Megan Kasetty

Open publisher page 6 citations

Abstract

PURPOSE: To determine whether small macular hole closure can be achieved with 25-G vitrectomy surgery with internal limiting membrane peeling without the use of intraocular gas tamponade or facedown positioning. METHODS: 25-G vitrectomy surgery with internal limiting membrane peeling without the use of intraocular gas tamponade or positioning was performed on 20 eyes with a small (<400-µm diameter), full-thickness macular hole. RESULTS: In 17 of 20 eyes (85%), the hole had closed. Three holes had closed by Postoperative Day 1, 13 holes by Postoperative Week 1, 16 holes by Postoperative Week 2, and 17 holes by Postoperative Week 6. At Postoperative Month 1, vision improved in 16 of 17 eyes in which the macular hole had closed. One hole that had not closed at the first postoperative week and two holes that had not closed at the third postoperative week required follow-up surgery with intraocular gas tamponade and facedown positioning, after which the hole closed. The mean preoperative visual acuity was 0.626 logMAR (20/85), and the mean postoperative visual acuity after 1 month was 0.392 logMAR (20/50) (P < 0.001). CONCLUSION: Vitrectomy surgery with internal limiting membrane peeling without the use of gas tamponade or positioning can achieve closure of small macular holes.

About this research paper

What this paper is about

PURPOSE: To determine whether small macular hole closure can be achieved with 25-G vitrectomy surgery with internal limiting membrane peeling without the use of intraocular gas tamponade or facedown positioning. METHODS: 25-G vitrectomy surgery with internal limiting membrane peeling without the use of intraocular gas tamponade or positioning was performed on 20 eyes with a small (<400-µm diameter), full-thickness macular hole. RESULTS: In 17 of 20 eyes (85%), the hole had closed. Three holes had closed by Postoperative Day 1, 13 holes by Postoperative Week 1, 16 holes by Postoperative Week 2, and 17 holes by Postoperative Week 6. At Postoperative Month 1, vision improved in 16 of 17 eyes in which the macular hole had closed. One hole that had not closed at the first postoperative week and two holes that had not closed at the third postoperative week required follow-up surgery with intraocular gas tamponade and facedown positioning, after which the hole closed. The mean preoperative visual acuity was 0.626 logMAR (20/85), and the mean postoperative visual acuity after 1 month was 0.392 logMAR (20/50) (P < 0.001). CONCLUSION: Vitrectomy surgery with internal limiting membrane peeling without the use of gas tamponade or positioning can achieve closure of small macular holes.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To determine whether small macular hole closure can be achieved with 25-G vitrectomy surgery with internal limiting membrane peeling without the use of intraocular gas tamponade or facedown positioning. METHODS: 25-G vitrectomy surgery with internal limiting membrane peeling without the use of intraocular gas tamponade or positioning was performed on 20 eyes with a small (<400-µm diameter), full-thickness macular hole. RESULTS: In 17 of 20 eyes (85%), the hole had closed. Three holes had closed by Postoperative Day 1, 13 holes by Postoperative Week 1, 16 holes by Postoperative Week 2, and 17 holes by Postoperative Week 6. At Postoperative Month 1, vision improved in 16 of 17 eyes in which the macular hole had closed. One hole that had not closed at the first postoperative week and two holes that had not closed at the third postoperative week required follow-up surgery with intraocular gas tamponade and facedown positioning, after which the hole closed. The mean preoperative visual acuity was 0.626 logMAR (20/85), and the mean postoperative visual acuity after 1 month was 0.392 logMAR (20/50) (P < 0.001). CONCLUSION: Vitrectomy surgery with internal limiting membrane peeling without the use of gas tamponade or positioning can achieve closure of small macular holes.

Key concepts: Macular hole, Tamponade, Vitrectomy, Internal limiting membrane, Medicine, Visual acuity, Ophthalmology, Intraocular pressure

Related papers

Back to paper searchBrowse research topicsOriginal source
CLOSURE OF SMALL MACULAR HOLES USING VITRECTOMY SURGERY WITH INTERNAL LIMITING MEMBRANE PEELING WITHOUT THE USE OF INTRAOCULAR GAS TAMPONADE: BROADENING THE UNDERSTANDING OF THE MACULAR HOLE PATHOPHYSIOLOGY — Research Paper | ScholarLens