2019Unpublished venueRequires access

Contact lens design to third order to compensate the spherical aberration of the eye from Zernike polynomials

O. García-Liévanos, Emiliano Terán, Luis A. Hernandez-Flores, Leticia Sanchez-Gonzalez

Open publisher page 1 citations

Abstract

To compensate the spherical aberration of the eye using the conic constant of the first surface of a contact lens for different refractive errors. Refractive errors were simulated by modifying only the first curvature of the cornea. For every refractive error was calculating Zernike polynomials using Optics Software for Layout and Optimization (OSLO) EDU edition with and without contact lens. To calculate the conic constant of the contact lens we use the Seidel sums for thin lenses from the longitudinal spherical aberration as it proposes V. Mahajan. The value of Zernike spherical aberration coefficient for the eye with farsightedness (+ 5.00 D) + spherical contact lens was 0.142691 μm. The conic constant value to compensate the spherical aberration was -0.222995 and the value of Zernike spherical aberration coefficient of the eye + aspherical contact lens was 0.004354 μm. The value of Zernike spherical aberration coefficient for the eye with myopia (- 5.00 D) + spherical contact lens was 0.144505 μm. The conic constant value to compensate the spherical aberration was -0.101424 and the value of Zernike spherical aberration coefficient of the eye + aspherical contact lens was 0.072820 μm. The proposed method allows us to design contact lenses that compensate for the spherical aberration of the eye from the Zernike polynomials. Although the design of contact lenses is to third order, we obtain a smaller spherical aberration than the chromatic aberration on the axis without use optimization routine.

About this research paper

What this paper is about

To compensate the spherical aberration of the eye using the conic constant of the first surface of a contact lens for different refractive errors. Refractive errors were simulated by modifying only the first curvature of the cornea. For every refractive error was calculating Zernike polynomials using Optics Software for Layout and Optimization (OSLO) EDU edition with and without contact lens. To calculate the conic constant of the contact lens we use the Seidel sums for thin lenses from the longitudinal spherical aberration as it proposes V. Mahajan. The value of Zernike spherical aberration coefficient for the eye with farsightedness (+ 5.00 D) + spherical contact lens was 0.142691 μm. The conic constant value to compensate the spherical aberration was -0.222995 and the value of Zernike spherical aberration coefficient of the eye + aspherical contact lens was 0.004354 μm. The value of Zernike spherical aberration coefficient for the eye with myopia (- 5.00 D) + spherical contact lens was 0.144505 μm. The conic constant value to compensate the spherical aberration was -0.101424 and the value of Zernike spherical aberration coefficient of the eye + aspherical contact lens was 0.072820 μm. The proposed method allows us to design contact lenses that compensate for the spherical aberration of the eye from the Zernike polynomials. Although the design of contact lenses is to third order, we obtain a smaller spherical aberration than the chromatic aberration on the axis without use optimization routine.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To compensate the spherical aberration of the eye using the conic constant of the first surface of a contact lens for different refractive errors. Refractive errors were simulated by modifying only the first curvature of the cornea. For every refractive error was calculating Zernike polynomials using Optics Software for Layout and Optimization (OSLO) EDU edition with and without contact lens. To calculate the conic constant of the contact lens we use the Seidel sums for thin lenses from the longitudinal spherical aberration as it proposes V. Mahajan. The value of Zernike spherical aberration coefficient for the eye with farsightedness (+ 5.00 D) + spherical contact lens was 0.142691 μm. The conic constant value to compensate the spherical aberration was -0.222995 and the value of Zernike spherical aberration coefficient of the eye + aspherical contact lens was 0.004354 μm. The value of Zernike spherical aberration coefficient for the eye with myopia (- 5.00 D) + spherical contact lens was 0.144505 μm. The conic constant value to compensate the spherical aberration was -0.101424 and the value of Zernike spherical aberration coefficient of the eye + aspherical contact lens was 0.072820 μm. The proposed method allows us to design contact lenses that compensate for the spherical aberration of the eye from the Zernike polynomials. Although the design of contact lenses is to third order, we obtain a smaller spherical aberration than the chromatic aberration on the axis without use optimization routine.

Key concepts: Zernike polynomials, Spherical aberration, Optics, Conic section, Lens (geology), Contact lens, Contrast transfer function, Physics

Related papers

Back to paper searchBrowse research topicsOriginal source
Contact lens design to third order to compensate the spherical aberration of the eye from Zernike polynomials — Research Paper | ScholarLens