불균일 피로균열을 갖는 CCT 시험편의 파괴인성실험의 유효성에 관한 실험적 고찰
오동준, 안상복, 김영석
Abstract
오동준, 안상복, 김영석
Abstract
The aim of this study is to demonstrate the validity of the fracture toughness of Zr-2.5Nb pressure tube obtained from the CCT (Curved Compact Tension) specimen with a non-uniformed pre-fatigue crack. This study covers the comparison of the J-R values of the CCT specimen taken from the unirradiated Zr-2.5Nb tubes with low and high fracture toughness and the irradiated Zr-2.5Nb tube with low fracture toughness, respectively. The fracture toughness tests were carried out at RT, 250 and 300℃. At high temperatures such as 250 or 300℃, it was found that the CCT specimen with the non-uniformed pre-fatigue crack has fracture toughness, dJ/da comparable to that of the CCT specimen with the uniform pre-fatigue irrespective of fracture toughness of Zr-2.5Nb pressure tube. In contrast, at RT, the CCT specimen with the non-uniformed pre-fatigue crack had different fracture toughness from that of the CCT specimen with the uniform pre-fatigue crack, which becomes non-conservative. Especially, the CCT specimens with the non-uniform pre-fatigue crack taken from both unirradiated and irradiated Zr-2.5Nb pressure tube of low fracture toughness yield lower fracture toughness than that of the CCT specimen with the uniform pre-fatigue crack, leading to a conservatism. Finally, using both yield strength correction constant, C₁, and fracture toughness growth ratio correction constant, C₂, it is possible to predict the fracture toughness of CCT specimen with the uniform pre-fatigue crack from the result of non-uniform pre-fatigue crack.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The aim of this study is to demonstrate the validity of the fracture toughness of Zr-2.5Nb pressure tube obtained from the CCT (Curved Compact Tension) specimen with a non-uniformed pre-fatigue crack. This study covers the comparison of the J-R values of the CCT specimen taken from the unirradiated Zr-2.5Nb tubes with low and high fracture toughness and the irradiated Zr-2.5Nb tube with low fracture toughness, respectively. The fracture toughness tests were carried out at RT, 250 and 300℃. At high temperatures such as 250 or 300℃, it was found that the CCT specimen with the non-uniformed pre-fatigue crack has fracture toughness, dJ/da comparable to that of the CCT specimen with the uniform pre-fatigue irrespective of fracture toughness of Zr-2.5Nb pressure tube. In contrast, at RT, the CCT specimen with the non-uniformed pre-fatigue crack had different fracture toughness from that of the CCT specimen with the uniform pre-fatigue crack, which becomes non-conservative. Especially, the CCT specimens with the non-uniform pre-fatigue crack taken from both unirradiated and irradiated Zr-2.5Nb pressure tube of low fracture toughness yield lower fracture toughness than that of the CCT specimen with the uniform pre-fatigue crack, leading to a conservatism. Finally, using both yield strength correction constant, C₁, and fracture toughness growth ratio correction constant, C₂, it is possible to predict the fracture toughness of CCT specimen with the uniform pre-fatigue crack from the result of non-uniform pre-fatigue crack.
Key concepts: Fracture toughness, Materials science, Compact tension specimen, Composite material, Pressure vessel, Toughness, Fracture (geology), Yield (engineering)