2019•Weed TechnologyOpen access

Spray mixture pH as affected by dicamba, glyphosate, and spray additives

Thomas C. Mueller, Lawrence E. Steckel

Open full text 42 citations

Abstract

Abstract The pH of spray mixtures is an important attribute that affects dicamba volatility under field conditions. This report examined the effect of different components added to water sources that ranged in initial pH from 4.6 to 8.4. Commercial products were used, which include formulations of dicamba, glyphosate, the drift retardant Intact, ammonium sulfate (AMS), and several pH modifiers. Adding BAPMA salt of dicamba always increased the mixture pH, whereas diglycolamine + VaporGrip® (DGA+VG) had a mixed response. The addition of AMS decreased pH slightly (usually <0.5 pH unit), whereas the addition of potassium salt of glyphosate (GLY-K) always decreased the measured pH (from 1.0 to 2.1 pH units). A substantial pH change could have profound effects on dicamba volatility. Moreover, the 1.0 to 2.1 pH units would not be consistent with the registrant’s report stating that GLY-K decreased mixtures with DGA+VG pH by only 0.2 to 0.3 units. The drift retardant Intact had no effect on pH. There was no difference in resultant pH when comparing K salt and isopropylamine (IPA) salts of glyphosate. Spray carrier volume, ranging from 94 to 187 L ha–1, had only a minor effect on measured pH after the addition of various spray components. The addition of selected pH modifiers raised the pH above 5.0, which is a critical value according to the latest dicamba application labels. The order of mixing of various pH modifiers, including AMS, had only limited effect on measured spray solution pH.

Open-access reader

About this research paper

What this paper is about

Abstract The pH of spray mixtures is an important attribute that affects dicamba volatility under field conditions. This report examined the effect of different components added to water sources that ranged in initial pH from 4.6 to 8.4. Commercial products were used, which include formulations of dicamba, glyphosate, the drift retardant Intact, ammonium sulfate (AMS), and several pH modifiers. Adding BAPMA salt of dicamba always increased the mixture pH, whereas diglycolamine + VaporGrip® (DGA+VG) had a mixed response. The addition of AMS decreased pH slightly (usually <0.5 pH unit), whereas the addition of potassium salt of glyphosate (GLY-K) always decreased the measured pH (from 1.0 to 2.1 pH units). A substantial pH change could have profound effects on dicamba volatility. Moreover, the 1.0 to 2.1 pH units would not be consistent with the registrant’s report stating that GLY-K decreased mixtures with DGA+VG pH by only 0.2 to 0.3 units. The drift retardant Intact had no effect on pH. There was no difference in resultant pH when comparing K salt and isopropylamine (IPA) salts of glyphosate. Spray carrier volume, ranging from 94 to 187 L ha–1, had only a minor effect on measured pH after the addition of various spray components. The addition of selected pH modifiers raised the pH above 5.0, which is a critical value according to the latest dicamba application labels. The order of mixing of various pH modifiers, including AMS, had only limited effect on measured spray solution pH.

Why it matters

OpenAlex reports 42 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract The pH of spray mixtures is an important attribute that affects dicamba volatility under field conditions. This report examined the effect of different components added to water sources that ranged in initial pH from 4.6 to 8.4. Commercial products were used, which include formulations of dicamba, glyphosate, the drift retardant Intact, ammonium sulfate (AMS), and several pH modifiers. Adding BAPMA salt of dicamba always increased the mixture pH, whereas diglycolamine + VaporGrip® (DGA+VG) had a mixed response. The addition of AMS decreased pH slightly (usually <0.5 pH unit), whereas the addition of potassium salt of glyphosate (GLY-K) always decreased the measured pH (from 1.0 to 2.1 pH units). A substantial pH change could have profound effects on dicamba volatility. Moreover, the 1.0 to 2.1 pH units would not be consistent with the registrant’s report stating that GLY-K decreased mixtures with DGA+VG pH by only 0.2 to 0.3 units. The drift retardant Intact had no effect on pH. There was no difference in resultant pH when comparing K salt and isopropylamine (IPA) salts of glyphosate. Spray carrier volume, ranging from 94 to 187 L ha–1, had only a minor effect on measured pH after the addition of various spray components. The addition of selected pH modifiers raised the pH above 5.0, which is a critical value according to the latest dicamba application labels. The order of mixing of various pH modifiers, including AMS, had only limited effect on measured spray solution pH.

Key concepts: Dicamba, Chemistry, Glyphosate, Salt (chemistry), Ammonium nitrate, Ammonia, Ammonium, Nuclear chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Spray mixture pH as affected by dicamba, glyphosate, and spray additives — Research Paper | ScholarLens