2019•Beni-Suef University Journal of Basic and Applied SciencesOpen access

Performance of single-sloped pitched roof cadmium telluride (CdTe) building-integrated photovoltaic system in tropical weather conditions

Nallapaneni Manoj Kumar

Open full text 11 citations

Abstract

This paper investigates the performance of a single-sloped pitched roof building-integrated photovoltaic (SSPR-BIPV) system. A typical rural building having a roof area of 60 sq. m is considered for the study. It was observed that the considered roof area could accommodate, nearly 7 kW BIPV system, and on the other side, most buildings seen in Malaysia are of the roof based constructed at different roof pitches. Considering this, a SSPR-BIPV is proposed and analyzed in seven different pitched roofs (the steepness of roof slopes are 15°, 18°, 22°, 30°, 35°, 40°, and 45°) under the tropical weather conditions in Malaysia. As per the study constraints, the 7 kW CdTe BIPV under seven different pitched roofs is capable of generating electricity within the range of 9510 to 7710 kWh. Performance ratio and energy losses for seven pitched roofs were identified to be in the range of 74.92 to 76.37% and − 23.63 to − 25.08% respectively. From the results, it is observed that in a BIPV system, as the building roof pitch increases, the energy yields and performance ratios tend to decrease, thereby increasing the overall energy losses. Hence, this study reveals that there exists a considerable influence of pitched roof over the BIPV performance and suggests using lower roof pitch angles during the installation of BIPV roof especially in the case tropical weather conditions.

About this research paper

What this paper is about

This paper investigates the performance of a single-sloped pitched roof building-integrated photovoltaic (SSPR-BIPV) system. A typical rural building having a roof area of 60 sq. m is considered for the study. It was observed that the considered roof area could accommodate, nearly 7 kW BIPV system, and on the other side, most buildings seen in Malaysia are of the roof based constructed at different roof pitches. Considering this, a SSPR-BIPV is proposed and analyzed in seven different pitched roofs (the steepness of roof slopes are 15°, 18°, 22°, 30°, 35°, 40°, and 45°) under the tropical weather conditions in Malaysia. As per the study constraints, the 7 kW CdTe BIPV under seven different pitched roofs is capable of generating electricity within the range of 9510 to 7710 kWh. Performance ratio and energy losses for seven pitched roofs were identified to be in the range of 74.92 to 76.37% and − 23.63 to − 25.08% respectively. From the results, it is observed that in a BIPV system, as the building roof pitch increases, the energy yields and performance ratios tend to decrease, thereby increasing the overall energy losses. Hence, this study reveals that there exists a considerable influence of pitched roof over the BIPV performance and suggests using lower roof pitch angles during the installation of BIPV roof especially in the case tropical weather conditions.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper investigates the performance of a single-sloped pitched roof building-integrated photovoltaic (SSPR-BIPV) system. A typical rural building having a roof area of 60 sq. m is considered for the study. It was observed that the considered roof area could accommodate, nearly 7 kW BIPV system, and on the other side, most buildings seen in Malaysia are of the roof based constructed at different roof pitches. Considering this, a SSPR-BIPV is proposed and analyzed in seven different pitched roofs (the steepness of roof slopes are 15°, 18°, 22°, 30°, 35°, 40°, and 45°) under the tropical weather conditions in Malaysia. As per the study constraints, the 7 kW CdTe BIPV under seven different pitched roofs is capable of generating electricity within the range of 9510 to 7710 kWh. Performance ratio and energy losses for seven pitched roofs were identified to be in the range of 74.92 to 76.37% and − 23.63 to − 25.08% respectively. From the results, it is observed that in a BIPV system, as the building roof pitch increases, the energy yields and performance ratios tend to decrease, thereby increasing the overall energy losses. Hence, this study reveals that there exists a considerable influence of pitched roof over the BIPV performance and suggests using lower roof pitch angles during the installation of BIPV roof especially in the case tropical weather conditions.

Key concepts: Roof, Building-integrated photovoltaics, Photovoltaic system, Environmental science, Range (aeronautics), Flat roof, Civil engineering, Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Performance of single-sloped pitched roof cadmium telluride (CdTe) building-integrated photovoltaic system in tropical weather conditions — Research Paper | ScholarLens