2019•International Journal of Low-Carbon TechnologiesOpen access

Experimental investigation and performance analysis of an Organic Rankine Cycle for low-temperature heat to electricity generation

Lili S. Wei, Zhenjun Ma, Xuemei Gong, Xiujuan Guo

Open full text 3 citations

Abstract

Abstract This paper presents experimental investigation of low-temperature heat to electricity generation system based on Organic Rankine Cycle (ORC) using R152a as the working fluid. Both energy efficiency and exergy efficiency were analyzed based on the experiments. Although energy efficiency was low to 5.0% when the evaporating and cooling temperatures were 65°C and 11°C, respectively, the exergy efficiency reached 25%, which showed great competitiveness among low-temperature heat utilization technologies. To reveal the energy recovery proportion from the waste heat, both energy extraction efficiency and exergy extraction efficiency as well as energy and exergy loss paths were analyzed. When the heat source was 65°C, 14.9% of the maximum possible thermal energy in the heat source was absorbed by the organic working fluid, and 10.7% was transferred to the cooling medium. The power output contributed 0.64%. A total of 1.8% of the exergy in the heat stream flowed to the cooling medium. The start-up work takes dramatically 0.16% and 1.7% of energy and exergy, respectively. Other energy and exergy loss occurs due to the irreversibility of the heat transfer process and expansion process. Cascade ORC system could enlarge the temperature difference of the heat stream and raise the power output. However, the energy efficiency of the multi-stage ORC system is lower than single-stage system, since there was a downward trend of the temperature of heat source for the latter stage. ORC cycle can lower the temperature of heat source to 45°C.

About this research paper

What this paper is about

Abstract This paper presents experimental investigation of low-temperature heat to electricity generation system based on Organic Rankine Cycle (ORC) using R152a as the working fluid. Both energy efficiency and exergy efficiency were analyzed based on the experiments. Although energy efficiency was low to 5.0% when the evaporating and cooling temperatures were 65°C and 11°C, respectively, the exergy efficiency reached 25%, which showed great competitiveness among low-temperature heat utilization technologies. To reveal the energy recovery proportion from the waste heat, both energy extraction efficiency and exergy extraction efficiency as well as energy and exergy loss paths were analyzed. When the heat source was 65°C, 14.9% of the maximum possible thermal energy in the heat source was absorbed by the organic working fluid, and 10.7% was transferred to the cooling medium. The power output contributed 0.64%. A total of 1.8% of the exergy in the heat stream flowed to the cooling medium. The start-up work takes dramatically 0.16% and 1.7% of energy and exergy, respectively. Other energy and exergy loss occurs due to the irreversibility of the heat transfer process and expansion process. Cascade ORC system could enlarge the temperature difference of the heat stream and raise the power output. However, the energy efficiency of the multi-stage ORC system is lower than single-stage system, since there was a downward trend of the temperature of heat source for the latter stage. ORC cycle can lower the temperature of heat source to 45°C.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract This paper presents experimental investigation of low-temperature heat to electricity generation system based on Organic Rankine Cycle (ORC) using R152a as the working fluid. Both energy efficiency and exergy efficiency were analyzed based on the experiments. Although energy efficiency was low to 5.0% when the evaporating and cooling temperatures were 65°C and 11°C, respectively, the exergy efficiency reached 25%, which showed great competitiveness among low-temperature heat utilization technologies. To reveal the energy recovery proportion from the waste heat, both energy extraction efficiency and exergy extraction efficiency as well as energy and exergy loss paths were analyzed. When the heat source was 65°C, 14.9% of the maximum possible thermal energy in the heat source was absorbed by the organic working fluid, and 10.7% was transferred to the cooling medium. The power output contributed 0.64%. A total of 1.8% of the exergy in the heat stream flowed to the cooling medium. The start-up work takes dramatically 0.16% and 1.7% of energy and exergy, respectively. Other energy and exergy loss occurs due to the irreversibility of the heat transfer process and expansion process. Cascade ORC system could enlarge the temperature difference of the heat stream and raise the power output. However, the energy efficiency of the multi-stage ORC system is lower than single-stage system, since there was a downward trend of the temperature of heat source for the latter stage. ORC cycle can lower the temperature of heat source to 45°C.

Key concepts: Organic Rankine cycle, Exergy, Exergy efficiency, Process engineering, Waste heat, Working fluid, Environmental science, Rankine cycle

Related papers

Back to paper searchBrowse research topicsOriginal source
Experimental investigation and performance analysis of an Organic Rankine Cycle for low-temperature heat to electricity generation — Research Paper | ScholarLens