2019•Open MedicineOpen access

Hounsfield Units on Lumbar Computed Tomography for Predicting Regional Bone Mineral Density

Kyung Joon Kim, Dong Hwan Kim, Jae Il Lee, Byung Kwan Choi, In Ho Han, Kyoung Hyup Nam

Open full text 143 citations

Abstract

Abstract Objective Bone mineral density (BMD) is a very important factor in spinal fusion surgery using instrumentation. Our aim was to investigate the utility of Hounsfield units (HU) obtained from preoperative lumbar computed tomography (CT) to predict osteoporosis coupling with data of quantitative computed tomography (QCT) and dual X-ray absorptiometry (DEXA). Methods We reviewed 180 patients that underwent both QCT and lumbar CT for spine surgery. HU was retrospectively calculated on the lumbar CT of 503 lumbar vertebrae from L1 to L3. Femur DEXA was performed in all patients and spine DEXA was tested in 120 patients (331 vertebrae). BMD was grouped as osteoporosis (QCT<80mg/cm 3 , DEXA T score≤-2.5) and non-osteoporosis (QCT≥80mg/cm 3 , DEXA T score>-2.5) for comparison of HU value. Results HU value and BMD showed significant correlations. The optima cut-off value based on QCT was higher than that of DEXA scans which had the best correlation for predicting osteoporosis. ROC curve analysis demonstrated that HU value with QCT of 146 has a sensitivity of 94.3% and a specificity of 87.5% for osteoporosis. Conclusions Significant correlation was found between HU measurement and BMD value. These findings provide evidence that HU measurement can be established as a means for predicting osteoporosis before spine fusion surgery with reduced radiation hazard.

Open-access reader

About this research paper

What this paper is about

Abstract Objective Bone mineral density (BMD) is a very important factor in spinal fusion surgery using instrumentation. Our aim was to investigate the utility of Hounsfield units (HU) obtained from preoperative lumbar computed tomography (CT) to predict osteoporosis coupling with data of quantitative computed tomography (QCT) and dual X-ray absorptiometry (DEXA). Methods We reviewed 180 patients that underwent both QCT and lumbar CT for spine surgery. HU was retrospectively calculated on the lumbar CT of 503 lumbar vertebrae from L1 to L3. Femur DEXA was performed in all patients and spine DEXA was tested in 120 patients (331 vertebrae). BMD was grouped as osteoporosis (QCT<80mg/cm 3 , DEXA T score≤-2.5) and non-osteoporosis (QCT≥80mg/cm 3 , DEXA T score>-2.5) for comparison of HU value. Results HU value and BMD showed significant correlations. The optima cut-off value based on QCT was higher than that of DEXA scans which had the best correlation for predicting osteoporosis. ROC curve analysis demonstrated that HU value with QCT of 146 has a sensitivity of 94.3% and a specificity of 87.5% for osteoporosis. Conclusions Significant correlation was found between HU measurement and BMD value. These findings provide evidence that HU measurement can be established as a means for predicting osteoporosis before spine fusion surgery with reduced radiation hazard.

Why it matters

OpenAlex reports 143 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Objective Bone mineral density (BMD) is a very important factor in spinal fusion surgery using instrumentation. Our aim was to investigate the utility of Hounsfield units (HU) obtained from preoperative lumbar computed tomography (CT) to predict osteoporosis coupling with data of quantitative computed tomography (QCT) and dual X-ray absorptiometry (DEXA). Methods We reviewed 180 patients that underwent both QCT and lumbar CT for spine surgery. HU was retrospectively calculated on the lumbar CT of 503 lumbar vertebrae from L1 to L3. Femur DEXA was performed in all patients and spine DEXA was tested in 120 patients (331 vertebrae). BMD was grouped as osteoporosis (QCT<80mg/cm 3 , DEXA T score≤-2.5) and non-osteoporosis (QCT≥80mg/cm 3 , DEXA T score>-2.5) for comparison of HU value. Results HU value and BMD showed significant correlations. The optima cut-off value based on QCT was higher than that of DEXA scans which had the best correlation for predicting osteoporosis. ROC curve analysis demonstrated that HU value with QCT of 146 has a sensitivity of 94.3% and a specificity of 87.5% for osteoporosis. Conclusions Significant correlation was found between HU measurement and BMD value. These findings provide evidence that HU measurement can be established as a means for predicting osteoporosis before spine fusion surgery with reduced radiation hazard.

Key concepts: Medicine, Hounsfield scale, Osteoporosis, Quantitative computed tomography, Bone mineral, Nuclear medicine, Lumbar vertebrae, Lumbar

Related papers

Back to paper searchBrowse research topicsOriginal source
Hounsfield Units on Lumbar Computed Tomography for Predicting Regional Bone Mineral Density — Research Paper | ScholarLens