2019BioResourcesOpen access

An evaluation of strength performance of the edge connections between cross-laminated timber panels reinforced with glass fiber-reinforced plastic

Yo-Jin Song, In-Hwan Lee, Soon-Il Hong

Open full text 5 citations

Abstract

The strength performance of edge connections between the cross-laminated timber (CLT) panels, as currently applied to CLT construction, was compared to that of connections reinforced with glass fiber-reinforced plastic (GFRP) by means of a tensile-type shearing test. In this study, the reinforced half-lapped connection is intended to prevent CLT from coming apart due to failure of self-tapping screws (STS) by bonding GFRP sheets to connections between CLT panels. The end-distance and edge-distance of this reinforced half-lapped connection were designed to equal 5D (where D is the fastener diameter) and 4D, respectively, which is shorter than the 6D recommended by European Technical Approval (ETA). Nevertheless, the yield strength was increased by 7%, and the stiffness by 92%, compared to the non-reinforced half-lapped connection. In addition, the internal spline connections using GFRP-reinforced plywood were 57 and 36% higher than the connection made up of LVB or plywood, respectively, and the energy dissipation percentages were 400 and 76%, respectively. These results indicate that the reinforcement effect of the connection by the GFRP was very significant. On the other hand, the half-lapped connection of the larch CLT improved the strength performance as the end-distance increased, and the end-distance had a greater effect on the strength performance than the edge-distance.

Open-access reader

About this research paper

What this paper is about

The strength performance of edge connections between the cross-laminated timber (CLT) panels, as currently applied to CLT construction, was compared to that of connections reinforced with glass fiber-reinforced plastic (GFRP) by means of a tensile-type shearing test. In this study, the reinforced half-lapped connection is intended to prevent CLT from coming apart due to failure of self-tapping screws (STS) by bonding GFRP sheets to connections between CLT panels. The end-distance and edge-distance of this reinforced half-lapped connection were designed to equal 5D (where D is the fastener diameter) and 4D, respectively, which is shorter than the 6D recommended by European Technical Approval (ETA). Nevertheless, the yield strength was increased by 7%, and the stiffness by 92%, compared to the non-reinforced half-lapped connection. In addition, the internal spline connections using GFRP-reinforced plywood were 57 and 36% higher than the connection made up of LVB or plywood, respectively, and the energy dissipation percentages were 400 and 76%, respectively. These results indicate that the reinforcement effect of the connection by the GFRP was very significant. On the other hand, the half-lapped connection of the larch CLT improved the strength performance as the end-distance increased, and the end-distance had a greater effect on the strength performance than the edge-distance.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The strength performance of edge connections between the cross-laminated timber (CLT) panels, as currently applied to CLT construction, was compared to that of connections reinforced with glass fiber-reinforced plastic (GFRP) by means of a tensile-type shearing test. In this study, the reinforced half-lapped connection is intended to prevent CLT from coming apart due to failure of self-tapping screws (STS) by bonding GFRP sheets to connections between CLT panels. The end-distance and edge-distance of this reinforced half-lapped connection were designed to equal 5D (where D is the fastener diameter) and 4D, respectively, which is shorter than the 6D recommended by European Technical Approval (ETA). Nevertheless, the yield strength was increased by 7%, and the stiffness by 92%, compared to the non-reinforced half-lapped connection. In addition, the internal spline connections using GFRP-reinforced plywood were 57 and 36% higher than the connection made up of LVB or plywood, respectively, and the energy dissipation percentages were 400 and 76%, respectively. These results indicate that the reinforcement effect of the connection by the GFRP was very significant. On the other hand, the half-lapped connection of the larch CLT improved the strength performance as the end-distance increased, and the end-distance had a greater effect on the strength performance than the edge-distance.

Key concepts: Fibre-reinforced plastic, Fastener, Materials science, Composite material, Structural engineering, Cross laminated timber, Ultimate tensile strength, Glass fiber

Related papers

Back to paper searchBrowse research topicsOriginal source
An evaluation of strength performance of the edge connections between cross-laminated timber panels reinforced with glass fiber-reinforced plastic — Research Paper | ScholarLens