A Clinical Prospective Study: Corneal alterations after cataract surgery with the technique of phacoemulsification

Angela I. Karekla, Charalampia Linardi, Antonios Morfopoulos, Ioannis K. Lamprinakis

Open full text 1 citations

Abstract

Abstract    The purpose of this study is to investigate the effect of ultrasound energy used during phacoemulsification on corneal structure, which is the most important refractive part of the eye. This will be achieved with the comparison of preoperative and postoperative parameters related to corneal thickness and endothelium and their correlation with clinical, intrasurgical and imaging diagnostic findings.    Methods: This is a clinical prospective study conducted in Evangelismos G.H.A. The patients’ enrollment was based on detailed medical history assessment, medication records as well as meticulous slit lamp examination, tonometry, best corrected visual acuity evaluation and thorough fundoscopy. Nuclear cataract sclerosis was evaluated with Lens Opacities Classification System III, and patients were scheduled for surgery. Preoperatively, with the use of specular microscopy (Tomey EM-3000; Tomey, Tennenlohe, Germany),  central corneal thickness and several endothelial indices were recorded. The same measurements took place the 1st, 7th and 30th postoperative day. All the surgical operations were done without complications.    Results: statistical analysis from preoperative and postoperative data showed that central corneal thickness, although elevated during the 1st and 7th postoperative day, did not present statistical significant difference in the final evaluation, with a mean elevation of only 3,9μm. Endothelial cell density levels though were reduced in all postoperative measurements (p<0,001). The final percentage endothelial cell loss was18,58%, with the most profound loss being accounted in the first postoperative week. Corneal edema and endothelial cell loss were correlated with poor visual acuity, reduced corneal curvature, increased nuclear sclerosis and prolonged time of ultrasound metrics.    Conclusion: the use of confocal microscopy is a useful tool in pointing significant differences of corneal structure after uneventfull cataract phacoemulsification. The evaluation of a larger cohort of patients and a prolonged follow up procedure could give further information concerning corneal alterations after surgery. Key words: cataract, phacoemulsification, cornea, lens, endothelium, ultrasound, confocal microscopy List of Abbreviations: CCT: central corneal thickness, SD: standard deviation, CV: coefficient of variation, , ECD: endothelial cell density, ECL%: endothelial cell loss%,

About this research paper

What this paper is about

Abstract    The purpose of this study is to investigate the effect of ultrasound energy used during phacoemulsification on corneal structure, which is the most important refractive part of the eye. This will be achieved with the comparison of preoperative and postoperative parameters related to corneal thickness and endothelium and their correlation with clinical, intrasurgical and imaging diagnostic findings.    Methods: This is a clinical prospective study conducted in Evangelismos G.H.A. The patients’ enrollment was based on detailed medical history assessment, medication records as well as meticulous slit lamp examination, tonometry, best corrected visual acuity evaluation and thorough fundoscopy. Nuclear cataract sclerosis was evaluated with Lens Opacities Classification System III, and patients were scheduled for surgery. Preoperatively, with the use of specular microscopy (Tomey EM-3000; Tomey, Tennenlohe, Germany),  central corneal thickness and several endothelial indices were recorded. The same measurements took place the 1st, 7th and 30th postoperative day. All the surgical operations were done without complications.    Results: statistical analysis from preoperative and postoperative data showed that central corneal thickness, although elevated during the 1st and 7th postoperative day, did not present statistical significant difference in the final evaluation, with a mean elevation of only 3,9μm. Endothelial cell density levels though were reduced in all postoperative measurements (p<0,001). The final percentage endothelial cell loss was18,58%, with the most profound loss being accounted in the first postoperative week. Corneal edema and endothelial cell loss were correlated with poor visual acuity, reduced corneal curvature, increased nuclear sclerosis and prolonged time of ultrasound metrics.    Conclusion: the use of confocal microscopy is a useful tool in pointing significant differences of corneal structure after uneventfull cataract phacoemulsification. The evaluation of a larger cohort of patients and a prolonged follow up procedure could give further information concerning corneal alterations after surgery. Key words: cataract, phacoemulsification, cornea, lens, endothelium, ultrasound, confocal microscopy List of Abbreviations: CCT: central corneal thickness, SD: standard deviation, CV: coefficient of variation, , ECD: endothelial cell density, ECL%: endothelial cell loss%,

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract    The purpose of this study is to investigate the effect of ultrasound energy used during phacoemulsification on corneal structure, which is the most important refractive part of the eye. This will be achieved with the comparison of preoperative and postoperative parameters related to corneal thickness and endothelium and their correlation with clinical, intrasurgical and imaging diagnostic findings.    Methods: This is a clinical prospective study conducted in Evangelismos G.H.A. The patients’ enrollment was based on detailed medical history assessment, medication records as well as meticulous slit lamp examination, tonometry, best corrected visual acuity evaluation and thorough fundoscopy. Nuclear cataract sclerosis was evaluated with Lens Opacities Classification System III, and patients were scheduled for surgery. Preoperatively, with the use of specular microscopy (Tomey EM-3000; Tomey, Tennenlohe, Germany),  central corneal thickness and several endothelial indices were recorded. The same measurements took place the 1st, 7th and 30th postoperative day. All the surgical operations were done without complications.    Results: statistical analysis from preoperative and postoperative data showed that central corneal thickness, although elevated during the 1st and 7th postoperative day, did not present statistical significant difference in the final evaluation, with a mean elevation of only 3,9μm. Endothelial cell density levels though were reduced in all postoperative measurements (p<0,001). The final percentage endothelial cell loss was18,58%, with the most profound loss being accounted in the first postoperative week. Corneal edema and endothelial cell loss were correlated with poor visual acuity, reduced corneal curvature, increased nuclear sclerosis and prolonged time of ultrasound metrics.    Conclusion: the use of confocal microscopy is a useful tool in pointing significant differences of corneal structure after uneventfull cataract phacoemulsification. The evaluation of a larger cohort of patients and a prolonged follow up procedure could give further information concerning corneal alterations after surgery. Key words: cataract, phacoemulsification, cornea, lens, endothelium, ultrasound, confocal microscopy List of Abbreviations: CCT: central corneal thickness, SD: standard deviation, CV: coefficient of variation, , ECD: endothelial cell density, ECL%: endothelial cell loss%,

Key concepts: Medicine, Phacoemulsification, Ophthalmology, Corneal endothelium, Visual acuity, Prospective cohort study, Cataract surgery, Ultrasound

Related papers

Back to paper searchBrowse research topicsOriginal source
A Clinical Prospective Study: Corneal alterations after cataract surgery with the technique of phacoemulsification — Research Paper | ScholarLens