2019•International journal of advance research, ideas and innovations in technologyRequires access

A DC-DC converter using dickson charge pump voltage multiplier

Jayalekshmi J. Prakash, G Sreedevi

Open publisher page 1 citations

Abstract

The system is used to boost 20 V (from a solar cell or other sources) to 400 V. The converter is used to obtain 400 V which needs for integrating to 400V DC bus. Interleaved boost converters at the input side and Dickson charge pump based voltage multiplier at the output side are the main parts. Single source or two independent sources can be used. The modified Dickson charge pump voltage multiplier results in lower voltage stress on each capacitor for its voltage multiplier circuit and less number of diodes. Interleaved boost converter and Dickson charge pump voltage multiplier have been studied, designed and simulated. The design, open loop simulation and closed-loop simulation of the interleaved boost DC-DC converter based on modified Dickson charge pump voltage multiplier were done and compared with a conventional boost converter. The desired output voltage (400V) obtained. From the simulation results, it is evident that the output ripple voltage of the system with modification exhibits fewer ripples and it offers continuous input current than the conventional one. Also, the voltage across the capacitor is reduced and become uniform. Hence low rated capacitors with the reduced size are needed. The hardware part for the interleaved boost DC-DC converter based on modified Dickson charge pump voltage multiplier and conventional boost converter with Dickson charge pump voltage multiplier was done and desired output was obtained.

About this research paper

What this paper is about

The system is used to boost 20 V (from a solar cell or other sources) to 400 V. The converter is used to obtain 400 V which needs for integrating to 400V DC bus. Interleaved boost converters at the input side and Dickson charge pump based voltage multiplier at the output side are the main parts. Single source or two independent sources can be used. The modified Dickson charge pump voltage multiplier results in lower voltage stress on each capacitor for its voltage multiplier circuit and less number of diodes. Interleaved boost converter and Dickson charge pump voltage multiplier have been studied, designed and simulated. The design, open loop simulation and closed-loop simulation of the interleaved boost DC-DC converter based on modified Dickson charge pump voltage multiplier were done and compared with a conventional boost converter. The desired output voltage (400V) obtained. From the simulation results, it is evident that the output ripple voltage of the system with modification exhibits fewer ripples and it offers continuous input current than the conventional one. Also, the voltage across the capacitor is reduced and become uniform. Hence low rated capacitors with the reduced size are needed. The hardware part for the interleaved boost DC-DC converter based on modified Dickson charge pump voltage multiplier and conventional boost converter with Dickson charge pump voltage multiplier was done and desired output was obtained.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The system is used to boost 20 V (from a solar cell or other sources) to 400 V. The converter is used to obtain 400 V which needs for integrating to 400V DC bus. Interleaved boost converters at the input side and Dickson charge pump based voltage multiplier at the output side are the main parts. Single source or two independent sources can be used. The modified Dickson charge pump voltage multiplier results in lower voltage stress on each capacitor for its voltage multiplier circuit and less number of diodes. Interleaved boost converter and Dickson charge pump voltage multiplier have been studied, designed and simulated. The design, open loop simulation and closed-loop simulation of the interleaved boost DC-DC converter based on modified Dickson charge pump voltage multiplier were done and compared with a conventional boost converter. The desired output voltage (400V) obtained. From the simulation results, it is evident that the output ripple voltage of the system with modification exhibits fewer ripples and it offers continuous input current than the conventional one. Also, the voltage across the capacitor is reduced and become uniform. Hence low rated capacitors with the reduced size are needed. The hardware part for the interleaved boost DC-DC converter based on modified Dickson charge pump voltage multiplier and conventional boost converter with Dickson charge pump voltage multiplier was done and desired output was obtained.

Key concepts: Voltage multiplier, Charge pump, Voltage doubler, Boost converter, Capacitor, Electrical engineering, Voltage, Ripple

Related papers

Back to paper searchBrowse research topicsOriginal source
A DC-DC converter using dickson charge pump voltage multiplier — Research Paper | ScholarLens