2019International Journal of Laboratory HematologyRequires access

Clinical performance evaluation of the new hematology analyzer Mindray BC‐6000

Yimin Shen, Jun Cao, Zhiying Zhou, Yong Wang, Yili Shen, Jun He

Open publisher page 9 citations

Abstract

INTRODUCTION: With the progression of blood analysis technology, hematology analyzers become more complex and diverse. How to choose a superb instrument is a challenge for the laboratories. In the essay, we studied whether the newest BC-6000 hematology analyzer meets the needs of a clinical hematology laboratory. METHODS: Methods comparison was performed using 350 blood samples from patients between different measurement procedures; the basic analytical performance was also tested, including the throughput, carryover, precision, and linearity in different modes. The flagging performances for blasts, immature granulocytes, and NRBC were compared with manual microscopy. RESULTS: ≥ 0.997). Repeatability and reproducibility were satisfactory at all testing levels. The functional sensitivity of leukocytes and platelets in the blood and leukocytes and erythrocytes in body fluid was excellent at the 20% CV level. BC-6000 and XN displayed very high correlations for complete blood count (CBC) parameters and very high consistency for leukocyte differentials and NRBC compared with manual microscopy. BC-6000 showed excellent sensitivity and specificity flagging ability on blasts (82.9% and 82.4%) and NRBC (80.0% and 96.9%). For immature granulocytes, BC-6000 showed excellent sensitivity but common specificity flagging ability (91.7% and 65.6%). CONCLUSION: The clinical performance of BC-6000 is excellent, and the analyzer can provide timely and accurate reporting for most of the small- to large-scale laboratories.

About this research paper

What this paper is about

INTRODUCTION: With the progression of blood analysis technology, hematology analyzers become more complex and diverse. How to choose a superb instrument is a challenge for the laboratories. In the essay, we studied whether the newest BC-6000 hematology analyzer meets the needs of a clinical hematology laboratory. METHODS: Methods comparison was performed using 350 blood samples from patients between different measurement procedures; the basic analytical performance was also tested, including the throughput, carryover, precision, and linearity in different modes. The flagging performances for blasts, immature granulocytes, and NRBC were compared with manual microscopy. RESULTS: ≥ 0.997). Repeatability and reproducibility were satisfactory at all testing levels. The functional sensitivity of leukocytes and platelets in the blood and leukocytes and erythrocytes in body fluid was excellent at the 20% CV level. BC-6000 and XN displayed very high correlations for complete blood count (CBC) parameters and very high consistency for leukocyte differentials and NRBC compared with manual microscopy. BC-6000 showed excellent sensitivity and specificity flagging ability on blasts (82.9% and 82.4%) and NRBC (80.0% and 96.9%). For immature granulocytes, BC-6000 showed excellent sensitivity but common specificity flagging ability (91.7% and 65.6%). CONCLUSION: The clinical performance of BC-6000 is excellent, and the analyzer can provide timely and accurate reporting for most of the small- to large-scale laboratories.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

INTRODUCTION: With the progression of blood analysis technology, hematology analyzers become more complex and diverse. How to choose a superb instrument is a challenge for the laboratories. In the essay, we studied whether the newest BC-6000 hematology analyzer meets the needs of a clinical hematology laboratory. METHODS: Methods comparison was performed using 350 blood samples from patients between different measurement procedures; the basic analytical performance was also tested, including the throughput, carryover, precision, and linearity in different modes. The flagging performances for blasts, immature granulocytes, and NRBC were compared with manual microscopy. RESULTS: ≥ 0.997). Repeatability and reproducibility were satisfactory at all testing levels. The functional sensitivity of leukocytes and platelets in the blood and leukocytes and erythrocytes in body fluid was excellent at the 20% CV level. BC-6000 and XN displayed very high correlations for complete blood count (CBC) parameters and very high consistency for leukocyte differentials and NRBC compared with manual microscopy. BC-6000 showed excellent sensitivity and specificity flagging ability on blasts (82.9% and 82.4%) and NRBC (80.0% and 96.9%). For immature granulocytes, BC-6000 showed excellent sensitivity but common specificity flagging ability (91.7% and 65.6%). CONCLUSION: The clinical performance of BC-6000 is excellent, and the analyzer can provide timely and accurate reporting for most of the small- to large-scale laboratories.

Key concepts: Hematology analyzer, Flagging, Repeatability, Hematology, Medicine, Reproducibility, Internal medicine, Pathology

Related papers

Back to paper searchBrowse research topicsOriginal source
Clinical performance evaluation of the new hematology analyzer Mindray BC‐6000 — Research Paper | ScholarLens