2019MATEC Web of ConferencesOpen access

The response of clay plaster to temperature and RH sinusoidal variations

Valeria Cascione, Denise Lim, Daniel Maskell, Andy Shea, Pete Walker

Open full text 4 citations

Abstract

Hygroscopic finishing materials can be used to moderate indoor humidity levels; they have the capacity to adsorb and release moisture from and to the surrounding air, depending on the indoor relative humidity levels. To determine the moisture buffering properties of materials several protocols have been introduced. However, testing procedures are based on a time-response method, where humidity variations are under a square wave function and temperature remains constant. Therefore, the ability of these methods to simulate material behaviour under real conditions, where cyclical humidity variations are more gradual, and temperature is variable, has been called into question. The aim of this study is to perform a standard moisture buffering test, by substituting the step-variation method, with a sinusoidal humidity function at different temperatures. Clay has been used to perform the tests in a climatic chamber, where a small increase of relative humidity have been set, in order to obtain a quasi-sinusoidal curve. The relative humidity variation are limited by low humidity (33% RH) and high humidity (75% RH) and temperature variation between 18 °C and 28 °C. Materials tested present a lag in the response to the peak relative humidity to peak mass gain, which suggests an alternative way to consider the rate of sorption and the moisture storage function. The significance of the paper is to develop a laboratory test that can be more readily compared with the behaviour real buildings, which operate under more of a sine waveform

Open-access reader

About this research paper

What this paper is about

Hygroscopic finishing materials can be used to moderate indoor humidity levels; they have the capacity to adsorb and release moisture from and to the surrounding air, depending on the indoor relative humidity levels. To determine the moisture buffering properties of materials several protocols have been introduced. However, testing procedures are based on a time-response method, where humidity variations are under a square wave function and temperature remains constant. Therefore, the ability of these methods to simulate material behaviour under real conditions, where cyclical humidity variations are more gradual, and temperature is variable, has been called into question. The aim of this study is to perform a standard moisture buffering test, by substituting the step-variation method, with a sinusoidal humidity function at different temperatures. Clay has been used to perform the tests in a climatic chamber, where a small increase of relative humidity have been set, in order to obtain a quasi-sinusoidal curve. The relative humidity variation are limited by low humidity (33% RH) and high humidity (75% RH) and temperature variation between 18 °C and 28 °C. Materials tested present a lag in the response to the peak relative humidity to peak mass gain, which suggests an alternative way to consider the rate of sorption and the moisture storage function. The significance of the paper is to develop a laboratory test that can be more readily compared with the behaviour real buildings, which operate under more of a sine waveform

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Hygroscopic finishing materials can be used to moderate indoor humidity levels; they have the capacity to adsorb and release moisture from and to the surrounding air, depending on the indoor relative humidity levels. To determine the moisture buffering properties of materials several protocols have been introduced. However, testing procedures are based on a time-response method, where humidity variations are under a square wave function and temperature remains constant. Therefore, the ability of these methods to simulate material behaviour under real conditions, where cyclical humidity variations are more gradual, and temperature is variable, has been called into question. The aim of this study is to perform a standard moisture buffering test, by substituting the step-variation method, with a sinusoidal humidity function at different temperatures. Clay has been used to perform the tests in a climatic chamber, where a small increase of relative humidity have been set, in order to obtain a quasi-sinusoidal curve. The relative humidity variation are limited by low humidity (33% RH) and high humidity (75% RH) and temperature variation between 18 °C and 28 °C. Materials tested present a lag in the response to the peak relative humidity to peak mass gain, which suggests an alternative way to consider the rate of sorption and the moisture storage function. The significance of the paper is to develop a laboratory test that can be more readily compared with the behaviour real buildings, which operate under more of a sine waveform

Key concepts: Relative humidity, Humidity, Moisture, Critical relative humidity, Environmental science, Water content, Materials science, Sorption

Related papers

Back to paper searchBrowse research topicsOriginal source
The response of clay plaster to temperature and RH sinusoidal variations — Research Paper | ScholarLens