2019Medicine and Pharmacy ReportsOpen access

Evaluation of antibacterial activity of three different glass ionomer cements on streptococcus mutans: an in-vitro antimicrobial study.

Chhaya Harin Khere, Hemalatha Hiremath, Sandesh Nagarajappa, Pooja Misar, Nishat Gorie

Open full text 10 citations

Abstract

AIM: Purpose of this in-vitro study was to assess and compare the antimicrobial activity of three different glass ionomer cements (GIC) against streptococcus mutans (S. mutans) bacteria using agar plate diffusion test. METHODS: Thirty blood agar plates were prepared and three wells of 4mm diameter were made on each agar plate. Three different GIC (Micron bioactive, GC Fuji IX GP Extra, Bioglass r) were mixed and filled into the wells. These plates were inoculated with S. Mutans and incubated at 37°C for 24 hours. Bacterial growth inhibition zone around each well were recorded in millimeters using Hiantibiotic Zonescale-C. RESULT: All the restorative material used in the study exhibited antimicrobial property against S. Mutans. GC Fuji IX GP Extra showed superior antimicrobial efficacy with 17.3±2.6 mm mean diameter of bacterial inhibition zone, followed by Micron bioactive 14.4±1.07 mm and Bioglass r 10.8 ± .91 mm inhibition zone respectively. CONCLUSION: Within the limitation of this study, it can be concluded that all the GIC evaluated demonstrated antibacterial activity against S. mutans. The superior antimicrobial activity was demonstrated by GC Fuji IX GP Extra. Hence, it could be advantageous in patients with high caries risk.

Open-access reader

About this research paper

What this paper is about

AIM: Purpose of this in-vitro study was to assess and compare the antimicrobial activity of three different glass ionomer cements (GIC) against streptococcus mutans (S. mutans) bacteria using agar plate diffusion test. METHODS: Thirty blood agar plates were prepared and three wells of 4mm diameter were made on each agar plate. Three different GIC (Micron bioactive, GC Fuji IX GP Extra, Bioglass r) were mixed and filled into the wells. These plates were inoculated with S. Mutans and incubated at 37°C for 24 hours. Bacterial growth inhibition zone around each well were recorded in millimeters using Hiantibiotic Zonescale-C. RESULT: All the restorative material used in the study exhibited antimicrobial property against S. Mutans. GC Fuji IX GP Extra showed superior antimicrobial efficacy with 17.3±2.6 mm mean diameter of bacterial inhibition zone, followed by Micron bioactive 14.4±1.07 mm and Bioglass r 10.8 ± .91 mm inhibition zone respectively. CONCLUSION: Within the limitation of this study, it can be concluded that all the GIC evaluated demonstrated antibacterial activity against S. mutans. The superior antimicrobial activity was demonstrated by GC Fuji IX GP Extra. Hence, it could be advantageous in patients with high caries risk.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

AIM: Purpose of this in-vitro study was to assess and compare the antimicrobial activity of three different glass ionomer cements (GIC) against streptococcus mutans (S. mutans) bacteria using agar plate diffusion test. METHODS: Thirty blood agar plates were prepared and three wells of 4mm diameter were made on each agar plate. Three different GIC (Micron bioactive, GC Fuji IX GP Extra, Bioglass r) were mixed and filled into the wells. These plates were inoculated with S. Mutans and incubated at 37°C for 24 hours. Bacterial growth inhibition zone around each well were recorded in millimeters using Hiantibiotic Zonescale-C. RESULT: All the restorative material used in the study exhibited antimicrobial property against S. Mutans. GC Fuji IX GP Extra showed superior antimicrobial efficacy with 17.3±2.6 mm mean diameter of bacterial inhibition zone, followed by Micron bioactive 14.4±1.07 mm and Bioglass r 10.8 ± .91 mm inhibition zone respectively. CONCLUSION: Within the limitation of this study, it can be concluded that all the GIC evaluated demonstrated antibacterial activity against S. mutans. The superior antimicrobial activity was demonstrated by GC Fuji IX GP Extra. Hence, it could be advantageous in patients with high caries risk.

Key concepts: Streptococcus mutans, Antimicrobial, Glass ionomer cement, Agar diffusion test, Agar, Agar plate, Chemistry, Antibacterial activity

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of antibacterial activity of three different glass ionomer cements on streptococcus mutans: an in-vitro antimicrobial study. — Research Paper | ScholarLens