Sonographic real-time imaging of tissue perfusion in a porcine haemorrhagic shock model
Wilma Schierling, Sabine Wipper, Christoph R. Behem, D. Hinck, Constantin Trepte, Eike Sebastian Debus, Karin Pfister
Abstract
Open-access reader
Wilma Schierling, Sabine Wipper, Christoph R. Behem, D. Hinck, Constantin Trepte, Eike Sebastian Debus, Karin Pfister
Abstract
Open-access reader
Injection of fluorescence-labelled microspheres (FMs) in pigs allows only the postmortem determination of organ perfusion. Colour duplex ultrasound (CDU) and contrast-enhanced ultrasound were established as techniques for real-time imaging of tissue perfusion in a porcine haemorrhagic shock model. Haemorrhagic shock was provoked in nine domestic pigs by taking at least 15% of the calculated blood volume. Ultrasound examinations were performed with a Hitachi HI VISION Ascendus. SonoVue was injected for contrast-enhanced ultrasound. Monitoring of the resistive index and time-to-peak ratio enabled quantification of tissue perfusion in vivo during the entire study, allowing real-time differentiation of animals with systemic shock versus failing shock effect. Postmortem analyses of injected FMs confirmed the sonographic in vivo results. Determination of the resistive index and time-to-peak ratio by CDU and contrast-enhanced ultrasound allowed real-time monitoring of tissue perfusion. Effects of haemorrhagic shock and therapeutic approaches related to organ perfusion can be observed live and in vivo.
OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Injection of fluorescence-labelled microspheres (FMs) in pigs allows only the postmortem determination of organ perfusion. Colour duplex ultrasound (CDU) and contrast-enhanced ultrasound were established as techniques for real-time imaging of tissue perfusion in a porcine haemorrhagic shock model. Haemorrhagic shock was provoked in nine domestic pigs by taking at least 15% of the calculated blood volume. Ultrasound examinations were performed with a Hitachi HI VISION Ascendus. SonoVue was injected for contrast-enhanced ultrasound. Monitoring of the resistive index and time-to-peak ratio enabled quantification of tissue perfusion in vivo during the entire study, allowing real-time differentiation of animals with systemic shock versus failing shock effect. Postmortem analyses of injected FMs confirmed the sonographic in vivo results. Determination of the resistive index and time-to-peak ratio by CDU and contrast-enhanced ultrasound allowed real-time monitoring of tissue perfusion. Effects of haemorrhagic shock and therapeutic approaches related to organ perfusion can be observed live and in vivo.
Key concepts: Perfusion, Ultrasound, Mechanical index, In vivo, Shock (circulatory), Medicine, Contrast-enhanced ultrasound, Blood volume