2019Journal of InstrumentationOpen access

Development of thermal neutron moderator for testing boron agents for Boron Neutron Capture Therapy (BNCT)

Go Ichikawa, Koji Tsuchida, Yoshiaki Kiyanagi, Akihisa Ishikawa, Yuho Hirata, Sachiko Yoshihashi, Kenichi Watanabe, Akira Uritani, Tsuyoshi Hamano, Ryo Ogawara, M. Suda, Kazuyo Igawa

Open full text 12 citations

Abstract

We developed a thermal neutron source for performance tests of boron agents for Boron Neutron Capture Therapy (BNCT) at Neutron exposure Accelerator System for Biological Effect Experiments (NASBEE) in National Institute of Radiological Sciences, Japan. The thermal neutron flux at the experimental position was measured to be 2.18 × 10 8 n/cm 2 /s, the cadmium ratio was 9.21, and gamma ray dose rate was 2.11 Gy/h. The neutron dose rate was estimated to be 2.96 Gy/h. These values indicate that the neutron source can be applicable for tests of boron agents although application range is limited. An example of irradiation experiment is described.

Open-access reader

About this research paper

What this paper is about

We developed a thermal neutron source for performance tests of boron agents for Boron Neutron Capture Therapy (BNCT) at Neutron exposure Accelerator System for Biological Effect Experiments (NASBEE) in National Institute of Radiological Sciences, Japan. The thermal neutron flux at the experimental position was measured to be 2.18 × 10 8 n/cm 2 /s, the cadmium ratio was 9.21, and gamma ray dose rate was 2.11 Gy/h. The neutron dose rate was estimated to be 2.96 Gy/h. These values indicate that the neutron source can be applicable for tests of boron agents although application range is limited. An example of irradiation experiment is described.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We developed a thermal neutron source for performance tests of boron agents for Boron Neutron Capture Therapy (BNCT) at Neutron exposure Accelerator System for Biological Effect Experiments (NASBEE) in National Institute of Radiological Sciences, Japan. The thermal neutron flux at the experimental position was measured to be 2.18 × 10 8 n/cm 2 /s, the cadmium ratio was 9.21, and gamma ray dose rate was 2.11 Gy/h. The neutron dose rate was estimated to be 2.96 Gy/h. These values indicate that the neutron source can be applicable for tests of boron agents although application range is limited. An example of irradiation experiment is described.

Key concepts: Neutron capture, Boron, Neutron temperature, Neutron source, Neutron, Radiochemistry, Materials science, Neutron moderator

Related papers

Back to paper searchBrowse research topicsOriginal source
Development of thermal neutron moderator for testing boron agents for Boron Neutron Capture Therapy (BNCT) — Research Paper | ScholarLens