2019Optical Measurement Systems for Industrial Inspection XIOpen access

Setup and evaluation of a static imaging Fourier transform spectrometer for the mid-infrared spectral range

Michael H. Köhler, The-Thien Nguyen, P. Kienle, Xingchen Dong, Alexander Koch

Open full text 1 citations

Abstract

Hyperspectral imaging is an established technique for process analysis capturing a two-dimensional spatial image and the spectral information for each pixel simultaneously. When moderate spectral resolution is sufficient, static imaging Fourier transform spectrometers (sIFTS) can offer a viable alternative to their scanning counterparts in the mid-infrared spectral range. Therefore, in this paper we present a sIFTS concept based on a single-mirror interferometer which shows no internal light losses and still works with extended light sources, achieving sufficient signal-to-noise ratios. The interferometer consists of a beam splitter, a plane mirror and a lens, which makes it both inexpensive and relatively easy to adjust. For a proof of principle we present a transmission measurement setup including a light source module, imaging optics and a single-mirror interferometer. The system achieves a spectral resolution of 12 cm−1 in a spectral range from 2700 cm−1 to 800 cm−1 , respectively from 3.7 μm to 13 μm. The spatial resolution amounts to about 10.10 lp/mm, the results for a sample containing different polymers show good agreement with a laboratory FTIR spectrometer.

About this research paper

What this paper is about

Hyperspectral imaging is an established technique for process analysis capturing a two-dimensional spatial image and the spectral information for each pixel simultaneously. When moderate spectral resolution is sufficient, static imaging Fourier transform spectrometers (sIFTS) can offer a viable alternative to their scanning counterparts in the mid-infrared spectral range. Therefore, in this paper we present a sIFTS concept based on a single-mirror interferometer which shows no internal light losses and still works with extended light sources, achieving sufficient signal-to-noise ratios. The interferometer consists of a beam splitter, a plane mirror and a lens, which makes it both inexpensive and relatively easy to adjust. For a proof of principle we present a transmission measurement setup including a light source module, imaging optics and a single-mirror interferometer. The system achieves a spectral resolution of 12 cm−1 in a spectral range from 2700 cm−1 to 800 cm−1 , respectively from 3.7 μm to 13 μm. The spatial resolution amounts to about 10.10 lp/mm, the results for a sample containing different polymers show good agreement with a laboratory FTIR spectrometer.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Hyperspectral imaging is an established technique for process analysis capturing a two-dimensional spatial image and the spectral information for each pixel simultaneously. When moderate spectral resolution is sufficient, static imaging Fourier transform spectrometers (sIFTS) can offer a viable alternative to their scanning counterparts in the mid-infrared spectral range. Therefore, in this paper we present a sIFTS concept based on a single-mirror interferometer which shows no internal light losses and still works with extended light sources, achieving sufficient signal-to-noise ratios. The interferometer consists of a beam splitter, a plane mirror and a lens, which makes it both inexpensive and relatively easy to adjust. For a proof of principle we present a transmission measurement setup including a light source module, imaging optics and a single-mirror interferometer. The system achieves a spectral resolution of 12 cm−1 in a spectral range from 2700 cm−1 to 800 cm−1 , respectively from 3.7 μm to 13 μm. The spatial resolution amounts to about 10.10 lp/mm, the results for a sample containing different polymers show good agreement with a laboratory FTIR spectrometer.

Key concepts: Optics, Spectral resolution, Interferometry, Spectrometer, Hyperspectral imaging, Beam splitter, Image resolution, Fourier transform

Related papers

Back to paper searchBrowse research topicsOriginal source
Setup and evaluation of a static imaging Fourier transform spectrometer for the mid-infrared spectral range — Research Paper | ScholarLens