Numerical Calculations of Multi-Channel Receiver Coil Array with High-Pass Spoke Coil for Parallel MRI
Han-Joong Kim, Phil Heo, Donghyuk Kim, Soobum Kim, Kyoung‐Nam Kim
Abstract
Han-Joong Kim, Phil Heo, Donghyuk Kim, Soobum Kim, Kyoung‐Nam Kim
Abstract
The proposed study reports the design and testing of spoke coil (SC), that compensates for the degradation in the g -factor that is caused by the insufficient sensitivity of the coil array along the main magnetic field direction. Electromagnetic (EM) simulations were performed to evaluate the performance of the proposed coil in a 7-T MRI system. 25-channel surface loop array and short dipole array containing SC or circular loop coil (LC) on the top of the phantom are 3D modeled. The SENSE g -factor and SNR of coil arrays are calculated and evaluated, and the quality factor ( Q ), scaling factor ( α ), and noise-corelated resistance ( R ) are considered. The directed effective magnetic field ( B 1 − ) generated by the SC improves the g -factor by compensating for the insufficient sensitivity information gathered by the array. However, this arrangement should be optimized to increase the available sensitivity information, depending on the type and structure of the coil elements in the array.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The proposed study reports the design and testing of spoke coil (SC), that compensates for the degradation in the g -factor that is caused by the insufficient sensitivity of the coil array along the main magnetic field direction. Electromagnetic (EM) simulations were performed to evaluate the performance of the proposed coil in a 7-T MRI system. 25-channel surface loop array and short dipole array containing SC or circular loop coil (LC) on the top of the phantom are 3D modeled. The SENSE g -factor and SNR of coil arrays are calculated and evaluated, and the quality factor ( Q ), scaling factor ( α ), and noise-corelated resistance ( R ) are considered. The directed effective magnetic field ( B 1 − ) generated by the SC improves the g -factor by compensating for the insufficient sensitivity information gathered by the array. However, this arrangement should be optimized to increase the available sensitivity information, depending on the type and structure of the coil elements in the array.
Key concepts: Electromagnetic coil, Sensitivity (control systems), Physics, Acoustics, Radiofrequency coil, Dipole, Imaging phantom, Nuclear magnetic resonance