2019Heat Transfer-Asian ResearchRequires access

Exergy analysis of a 1.2 MW waste heat power generation project

Zhonglan Hou, Long Shao, Xinli Wei, Xinling Ma, Tan Wu

Open publisher page 2 citations

Abstract

Abstract According to systematic features, analysis method based on exergy balance is established. Basic indicators in the system, the subsystem, and facilities are put forward in this paper. By using this method to analyze the generation system of megawatt‐scale in one chemical enterprise, it is found that the objective exergy efficiency of the system is 35.67%, and exergy loss of organic Rankine cycle (ORC) is the highest. The thermal efficiency of the total system is 9.61%. For the condenser, the thermal efficiency is 91.18%, and the exergy efficiency is only 23.44%. The objective exergy efficiency of the evaporator is 74.04%. The influence coefficient of exergy loss of condenser is higher than that of pump and expander, but input exergy of the condenser is lower than that of the expander. It is revealed that ORC subsystem is the part which needs to be focused on, and the condenser is the most important component of ORC subsystem which should be optimized firstly.

About this research paper

What this paper is about

Abstract According to systematic features, analysis method based on exergy balance is established. Basic indicators in the system, the subsystem, and facilities are put forward in this paper. By using this method to analyze the generation system of megawatt‐scale in one chemical enterprise, it is found that the objective exergy efficiency of the system is 35.67%, and exergy loss of organic Rankine cycle (ORC) is the highest. The thermal efficiency of the total system is 9.61%. For the condenser, the thermal efficiency is 91.18%, and the exergy efficiency is only 23.44%. The objective exergy efficiency of the evaporator is 74.04%. The influence coefficient of exergy loss of condenser is higher than that of pump and expander, but input exergy of the condenser is lower than that of the expander. It is revealed that ORC subsystem is the part which needs to be focused on, and the condenser is the most important component of ORC subsystem which should be optimized firstly.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract According to systematic features, analysis method based on exergy balance is established. Basic indicators in the system, the subsystem, and facilities are put forward in this paper. By using this method to analyze the generation system of megawatt‐scale in one chemical enterprise, it is found that the objective exergy efficiency of the system is 35.67%, and exergy loss of organic Rankine cycle (ORC) is the highest. The thermal efficiency of the total system is 9.61%. For the condenser, the thermal efficiency is 91.18%, and the exergy efficiency is only 23.44%. The objective exergy efficiency of the evaporator is 74.04%. The influence coefficient of exergy loss of condenser is higher than that of pump and expander, but input exergy of the condenser is lower than that of the expander. It is revealed that ORC subsystem is the part which needs to be focused on, and the condenser is the most important component of ORC subsystem which should be optimized firstly.

Key concepts: Exergy, Condenser (optics), Organic Rankine cycle, Evaporator, Exergy efficiency, Process engineering, Environmental science, Waste heat

Related papers

Back to paper searchBrowse research topicsOriginal source