2010arXiv (Cornell University)Open access

Standardization of 241Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting

C. Balpardo, M.E. Capoulat, Darío Rodrigues, P. Arenillas

Open full text 0 citations

Abstract

The nuclide 241Am decays by alpha emission to 237Np. Most of the decays (84.6 %) populate the excited level of 237Np with energy of 59.54 keV. Digital Coincidence Counting was applied to standardize a solution of 241Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid Scintillation Counting using the logical sum of double coincidences in a TDCR array and Defined Solid Angle Counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

Open-access reader

About this research paper

What this paper is about

The nuclide 241Am decays by alpha emission to 237Np. Most of the decays (84.6 %) populate the excited level of 237Np with energy of 59.54 keV. Digital Coincidence Counting was applied to standardize a solution of 241Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid Scintillation Counting using the logical sum of double coincidences in a TDCR array and Defined Solid Angle Counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The nuclide 241Am decays by alpha emission to 237Np. Most of the decays (84.6 %) populate the excited level of 237Np with energy of 59.54 keV. Digital Coincidence Counting was applied to standardize a solution of 241Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid Scintillation Counting using the logical sum of double coincidences in a TDCR array and Defined Solid Angle Counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

Key concepts: Liquid scintillation counting, Coincidence counting, Coincidence, Nuclide, Extrapolation, Solid angle, Ampoule, Physics

Related papers

Back to paper searchBrowse research topicsOriginal source
Standardization of 241Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting — Research Paper | ScholarLens