2019Acta Radiologica OpenOpen access

Iterative CT reconstruction in abdominal low-dose CT used for hybrid SPECT-CT applications: effect on image quality, image noise, detectability, and reader’s confidence

Oliver S. Großer, Juri Ruf, Dennis Kupitz, Damian Czuczwara, David Loewenthal, M Thormann, Christian Furth, Jens Ricke, Timm Denecke, Maciej Pech, Michael C. Kreißl, Holger Amthauer

Open full text 18 citations

Abstract

Background Iterative computed tomography (CT) image reconstruction shows high potential for the preservation of image quality in diagnostic CT while reducing patients’ exposure; it has become available for low-dose CT (LD-CT) in high-end hybrid imaging systems (e.g. single-photon emission computed tomography [SPECT]-CT). Purpose To examine the effect of an iterative CT reconstruction algorithm on image quality, image noise, detectability, and the reader’s confidence for LD-CT data by a subjective assessment. Material and Methods The LD-CT data were validated for 40 patients examined by an abdominal hybrid SPECT-CT (U = 120 kV, I = 40 mA, pitch = 1.375). LD-CT was reconstructed using either filtered back projection (FBP) or an iterative image reconstruction algorithm (Adaptive Statistical Iterative Reconstruction [ASIR]®) with different parameters (ASIR levels 50% and 100%). The data were validated by two independent blinded readers using a scoring system for image quality, image noise, detectability, and reader confidence, for a predefined set of 16 anatomic substructures. Results The image quality was significantly improved by iterative reconstruction of the LD-CT data compared with FBP ( P ≤ 0.0001). While detectability increased in only 2/16 structures ( P ≤ 0.03), the reader’s confidence increased significantly due to iterative reconstruction ( P ≤ 0.002). Meanwhile, at the ASIR level of 100%, the detectability in bone structure was highly reduced ( P = 0.003). Conclusion An ASIR level of 50% represents a good compromise in abdominal LD-CT image reconstruction. The specific ASIR level improved image quality (reduced image noise) and reader confidence, while preserving detectability of bone structure.

Open-access reader

About this research paper

What this paper is about

Background Iterative computed tomography (CT) image reconstruction shows high potential for the preservation of image quality in diagnostic CT while reducing patients’ exposure; it has become available for low-dose CT (LD-CT) in high-end hybrid imaging systems (e.g. single-photon emission computed tomography [SPECT]-CT). Purpose To examine the effect of an iterative CT reconstruction algorithm on image quality, image noise, detectability, and the reader’s confidence for LD-CT data by a subjective assessment. Material and Methods The LD-CT data were validated for 40 patients examined by an abdominal hybrid SPECT-CT (U = 120 kV, I = 40 mA, pitch = 1.375). LD-CT was reconstructed using either filtered back projection (FBP) or an iterative image reconstruction algorithm (Adaptive Statistical Iterative Reconstruction [ASIR]®) with different parameters (ASIR levels 50% and 100%). The data were validated by two independent blinded readers using a scoring system for image quality, image noise, detectability, and reader confidence, for a predefined set of 16 anatomic substructures. Results The image quality was significantly improved by iterative reconstruction of the LD-CT data compared with FBP ( P ≤ 0.0001). While detectability increased in only 2/16 structures ( P ≤ 0.03), the reader’s confidence increased significantly due to iterative reconstruction ( P ≤ 0.002). Meanwhile, at the ASIR level of 100%, the detectability in bone structure was highly reduced ( P = 0.003). Conclusion An ASIR level of 50% represents a good compromise in abdominal LD-CT image reconstruction. The specific ASIR level improved image quality (reduced image noise) and reader confidence, while preserving detectability of bone structure.

Why it matters

OpenAlex reports 18 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background Iterative computed tomography (CT) image reconstruction shows high potential for the preservation of image quality in diagnostic CT while reducing patients’ exposure; it has become available for low-dose CT (LD-CT) in high-end hybrid imaging systems (e.g. single-photon emission computed tomography [SPECT]-CT). Purpose To examine the effect of an iterative CT reconstruction algorithm on image quality, image noise, detectability, and the reader’s confidence for LD-CT data by a subjective assessment. Material and Methods The LD-CT data were validated for 40 patients examined by an abdominal hybrid SPECT-CT (U = 120 kV, I = 40 mA, pitch = 1.375). LD-CT was reconstructed using either filtered back projection (FBP) or an iterative image reconstruction algorithm (Adaptive Statistical Iterative Reconstruction [ASIR]®) with different parameters (ASIR levels 50% and 100%). The data were validated by two independent blinded readers using a scoring system for image quality, image noise, detectability, and reader confidence, for a predefined set of 16 anatomic substructures. Results The image quality was significantly improved by iterative reconstruction of the LD-CT data compared with FBP ( P ≤ 0.0001). While detectability increased in only 2/16 structures ( P ≤ 0.03), the reader’s confidence increased significantly due to iterative reconstruction ( P ≤ 0.002). Meanwhile, at the ASIR level of 100%, the detectability in bone structure was highly reduced ( P = 0.003). Conclusion An ASIR level of 50% represents a good compromise in abdominal LD-CT image reconstruction. The specific ASIR level improved image quality (reduced image noise) and reader confidence, while preserving detectability of bone structure.

Key concepts: Iterative reconstruction, Image quality, Image noise, Nuclear medicine, Tomography, Radon transform, Noise (video), Single-photon emission computed tomography

Related papers

Back to paper searchBrowse research topicsOriginal source
Iterative CT reconstruction in abdominal low-dose CT used for hybrid SPECT-CT applications: effect on image quality, image noise, detectability, and reader’s confidence — Research Paper | ScholarLens