2018•Anesthesia Essays and ResearchesOpen access

Evaluation and comparison of clonidine and dexmedetomidine for attenuation of hemodynamic response to laryngoscopy and intubation: A randomized controlled study

Sana Yasmin Hussain, Abhijit Karmarkar, Dhruv Jain

Open full text 15 citations

Abstract

BACKGROUND: Laryngoscopy and tracheal intubation are noxious stimuli which evoke a transient but marked sympathetic response. Alpha-2 adrenoceptor agonists attenuate the sympathoadrenal responses by inhibiting noradrenaline release. AIM: This study aims to evaluate and compare the effect of intravenous dexmedetomidine and clonidine on cardiovascular response resulting from laryngoscopy and endotracheal intubation. SETTINGS AND DESIGN: This was a prospective randomized controlled study carried out in the operating room. MATERIALS AND METHODS: Ninety American Society of Anesthesiologists Physical Status I and II patients were randomly allocated into three groups, that is, Group C (clonidine 2 μg/kg), Group D (dexmedetomidine 1 μg/kg), and Group S (normal saline) infused over 10 min. Blood pressures - systolic (SBP) and diastolic (DBP), mean arterial pressure (MAP), and heart rate (HR) were recorded after drug administration and intubation at subsequent intervals. STATISTICAL ANALYSIS USED: < 0.05 was considered statistically significant. RESULTS: HR, SBP, DBP, and MAP were lower in Group C and D compared to Group S at all times measured. HR was significantly lower in Group D compared to Group C after drug infusion. At 1 min after intubation, SBP and MAP were lower in Group D compared to Group C. At 3, 5, and 10 min after intubation, SBP, DBP, and MAP were lower in Group D compared to Group C. CONCLUSION: There was significant reduction in hemodynamic response by dexmedetomidine and clonidine as compared to controls. Furthermore, attenuation of the pressor response to intubation was better following premedication with dexmedetomidine than with clonidine.

About this research paper

What this paper is about

BACKGROUND: Laryngoscopy and tracheal intubation are noxious stimuli which evoke a transient but marked sympathetic response. Alpha-2 adrenoceptor agonists attenuate the sympathoadrenal responses by inhibiting noradrenaline release. AIM: This study aims to evaluate and compare the effect of intravenous dexmedetomidine and clonidine on cardiovascular response resulting from laryngoscopy and endotracheal intubation. SETTINGS AND DESIGN: This was a prospective randomized controlled study carried out in the operating room. MATERIALS AND METHODS: Ninety American Society of Anesthesiologists Physical Status I and II patients were randomly allocated into three groups, that is, Group C (clonidine 2 μg/kg), Group D (dexmedetomidine 1 μg/kg), and Group S (normal saline) infused over 10 min. Blood pressures - systolic (SBP) and diastolic (DBP), mean arterial pressure (MAP), and heart rate (HR) were recorded after drug administration and intubation at subsequent intervals. STATISTICAL ANALYSIS USED: < 0.05 was considered statistically significant. RESULTS: HR, SBP, DBP, and MAP were lower in Group C and D compared to Group S at all times measured. HR was significantly lower in Group D compared to Group C after drug infusion. At 1 min after intubation, SBP and MAP were lower in Group D compared to Group C. At 3, 5, and 10 min after intubation, SBP, DBP, and MAP were lower in Group D compared to Group C. CONCLUSION: There was significant reduction in hemodynamic response by dexmedetomidine and clonidine as compared to controls. Furthermore, attenuation of the pressor response to intubation was better following premedication with dexmedetomidine than with clonidine.

Why it matters

OpenAlex reports 15 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Laryngoscopy and tracheal intubation are noxious stimuli which evoke a transient but marked sympathetic response. Alpha-2 adrenoceptor agonists attenuate the sympathoadrenal responses by inhibiting noradrenaline release. AIM: This study aims to evaluate and compare the effect of intravenous dexmedetomidine and clonidine on cardiovascular response resulting from laryngoscopy and endotracheal intubation. SETTINGS AND DESIGN: This was a prospective randomized controlled study carried out in the operating room. MATERIALS AND METHODS: Ninety American Society of Anesthesiologists Physical Status I and II patients were randomly allocated into three groups, that is, Group C (clonidine 2 μg/kg), Group D (dexmedetomidine 1 μg/kg), and Group S (normal saline) infused over 10 min. Blood pressures - systolic (SBP) and diastolic (DBP), mean arterial pressure (MAP), and heart rate (HR) were recorded after drug administration and intubation at subsequent intervals. STATISTICAL ANALYSIS USED: < 0.05 was considered statistically significant. RESULTS: HR, SBP, DBP, and MAP were lower in Group C and D compared to Group S at all times measured. HR was significantly lower in Group D compared to Group C after drug infusion. At 1 min after intubation, SBP and MAP were lower in Group D compared to Group C. At 3, 5, and 10 min after intubation, SBP, DBP, and MAP were lower in Group D compared to Group C. CONCLUSION: There was significant reduction in hemodynamic response by dexmedetomidine and clonidine as compared to controls. Furthermore, attenuation of the pressor response to intubation was better following premedication with dexmedetomidine than with clonidine.

Key concepts: Dexmedetomidine, Clonidine, Anesthesia, Medicine, Laryngoscopy, Intubation, Mean arterial pressure, Haemodynamic response

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation and comparison of clonidine and dexmedetomidine for attenuation of hemodynamic response to laryngoscopy and intubation: A randomized controlled study — Research Paper | ScholarLens