2018•Unpublished venueRequires access

In Vitro Comparison Microleakage of Convectional Fissure Sealant and Icon Resin Infiltration

Mehrdad Barekatain, davood ghasemi toudeshkchui, Mehri Safari, shima omidi

Open publisher page 0 citations

Abstract

Introduction: Fissure sealant is used to reduce the incidence of occlusal decays. Recently, resin substances have been significantly developed, one of which is infiltrating resin Icon .This study aimed to compare fissure sealant from 3M ESPE and infiltrating resin in terms of microleakage. Materials and Methods: This experimental study was conducted on 40 extracted premolars with no decay and crack. These teeth were divided into two groups. The striae of occlusal surfaces of the teeth were covered by fissure sealant from 3M ESPE and infiltrating Icon resin according to the manufacturer’s recommendation. Thereafter, the teeth were thermocycled 500 times between 5°C to 55°C and finally placed in distilled water. The apex of all the teeth and divergence of the roots were sealed by sealing wax. The whole surfaces of dental root and crown were coated with two layers of nail varnish 1 mm from the sealant margin. The teeth were put in 0.5 volatile fuchsine at the temperature of 37°C to allow the coloring agent to penetrate to possible gaps between enamel and sealant. Then, the teeth were washed and cut off parallel to linear axis. The samples were studied in order to assess the amount of microleakage under the stereomicroscope with 36× magnification. The leakage was scored from 0 to 3. Data analysis was performed using Mann-Whitney U test. Results: There was no significant difference between fissure sealant from 3M ESPE and infiltrating resin in terms of microleakage (P=0.512). Conclusion: According to the results, the use of fissure sealant was more cost-effective and less time-consuming than the Icon material.

About this research paper

What this paper is about

Introduction: Fissure sealant is used to reduce the incidence of occlusal decays. Recently, resin substances have been significantly developed, one of which is infiltrating resin Icon .This study aimed to compare fissure sealant from 3M ESPE and infiltrating resin in terms of microleakage. Materials and Methods: This experimental study was conducted on 40 extracted premolars with no decay and crack. These teeth were divided into two groups. The striae of occlusal surfaces of the teeth were covered by fissure sealant from 3M ESPE and infiltrating Icon resin according to the manufacturer’s recommendation. Thereafter, the teeth were thermocycled 500 times between 5°C to 55°C and finally placed in distilled water. The apex of all the teeth and divergence of the roots were sealed by sealing wax. The whole surfaces of dental root and crown were coated with two layers of nail varnish 1 mm from the sealant margin. The teeth were put in 0.5 volatile fuchsine at the temperature of 37°C to allow the coloring agent to penetrate to possible gaps between enamel and sealant. Then, the teeth were washed and cut off parallel to linear axis. The samples were studied in order to assess the amount of microleakage under the stereomicroscope with 36× magnification. The leakage was scored from 0 to 3. Data analysis was performed using Mann-Whitney U test. Results: There was no significant difference between fissure sealant from 3M ESPE and infiltrating resin in terms of microleakage (P=0.512). Conclusion: According to the results, the use of fissure sealant was more cost-effective and less time-consuming than the Icon material.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Introduction: Fissure sealant is used to reduce the incidence of occlusal decays. Recently, resin substances have been significantly developed, one of which is infiltrating resin Icon .This study aimed to compare fissure sealant from 3M ESPE and infiltrating resin in terms of microleakage. Materials and Methods: This experimental study was conducted on 40 extracted premolars with no decay and crack. These teeth were divided into two groups. The striae of occlusal surfaces of the teeth were covered by fissure sealant from 3M ESPE and infiltrating Icon resin according to the manufacturer’s recommendation. Thereafter, the teeth were thermocycled 500 times between 5°C to 55°C and finally placed in distilled water. The apex of all the teeth and divergence of the roots were sealed by sealing wax. The whole surfaces of dental root and crown were coated with two layers of nail varnish 1 mm from the sealant margin. The teeth were put in 0.5 volatile fuchsine at the temperature of 37°C to allow the coloring agent to penetrate to possible gaps between enamel and sealant. Then, the teeth were washed and cut off parallel to linear axis. The samples were studied in order to assess the amount of microleakage under the stereomicroscope with 36× magnification. The leakage was scored from 0 to 3. Data analysis was performed using Mann-Whitney U test. Results: There was no significant difference between fissure sealant from 3M ESPE and infiltrating resin in terms of microleakage (P=0.512). Conclusion: According to the results, the use of fissure sealant was more cost-effective and less time-consuming than the Icon material.

Key concepts: Sealant, Dentistry, Stereo microscope, Fissure, Varnish, Materials science, Enamel paint, Composite material

Related papers

Back to paper searchBrowse research topicsOriginal source
In Vitro Comparison Microleakage of Convectional Fissure Sealant and Icon Resin Infiltration — Research Paper | ScholarLens