2018•JACOWOpen access

Low Power Measurement of a 1300-MHz RFQ Cold Model

Yasuhiro Kondo, Takatoshi Morishita, M. Otani, Jun Tamura

Open full text 0 citations

Abstract

A muon linac development for a new muon g-2/EDM experiment is now going on at J-PARC. Muons from the muon beam line (H-line) of the J-PARC muon facility are once stopped in a silica aerojel target and room temperature muoniums are evaporated from the aerogel. They are dissociated with the lasers to be the ultra slow muons, then accelerated up to 212 MeV using a linear accelerator. The low energy part of this muon linac consists of a 324-MHz RFQ and an IH DTL. The frequency is increased to 1296 MHz at the following CCL section. We propose to replace the low energy section to a 1300-MHz RFQ to simplify the configuration of the muon linac. The 1300-MHz RFQ will be extremely small compared to conventional RFQs, therefore we made a cold model to proof the feasibility of this scheme. In this paper, the result of low-power measurement of the 1300-MHz RFQ cold model is described.

About this research paper

What this paper is about

A muon linac development for a new muon g-2/EDM experiment is now going on at J-PARC. Muons from the muon beam line (H-line) of the J-PARC muon facility are once stopped in a silica aerojel target and room temperature muoniums are evaporated from the aerogel. They are dissociated with the lasers to be the ultra slow muons, then accelerated up to 212 MeV using a linear accelerator. The low energy part of this muon linac consists of a 324-MHz RFQ and an IH DTL. The frequency is increased to 1296 MHz at the following CCL section. We propose to replace the low energy section to a 1300-MHz RFQ to simplify the configuration of the muon linac. The 1300-MHz RFQ will be extremely small compared to conventional RFQs, therefore we made a cold model to proof the feasibility of this scheme. In this paper, the result of low-power measurement of the 1300-MHz RFQ cold model is described.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A muon linac development for a new muon g-2/EDM experiment is now going on at J-PARC. Muons from the muon beam line (H-line) of the J-PARC muon facility are once stopped in a silica aerojel target and room temperature muoniums are evaporated from the aerogel. They are dissociated with the lasers to be the ultra slow muons, then accelerated up to 212 MeV using a linear accelerator. The low energy part of this muon linac consists of a 324-MHz RFQ and an IH DTL. The frequency is increased to 1296 MHz at the following CCL section. We propose to replace the low energy section to a 1300-MHz RFQ to simplify the configuration of the muon linac. The 1300-MHz RFQ will be extremely small compared to conventional RFQs, therefore we made a cold model to proof the feasibility of this scheme. In this paper, the result of low-power measurement of the 1300-MHz RFQ cold model is described.

Key concepts: Power (physics), Physics, Quantum mechanics

Related papers

Back to paper searchBrowse research topicsOriginal source
Low Power Measurement of a 1300-MHz RFQ Cold Model — Research Paper | ScholarLens