2019•Journal of Wrist SurgeryOpen access

Biomechanical Comparison of Flexor Digitorum Profundus Avulsion Repair

Jill G. Putnam, Damon C Adamany

Open full text 8 citations

Abstract

Purpose Multiple repair techniques have been investigated for flexor digitorum profundus (FDP) tendon avulsions. The purpose of this study is to compare the biomechanical characteristics of a new fully threaded titanium suture anchor with previously examined fixation techniques. Methods Repair of FDP tendon avulsions was performed in 18 fresh-frozen cadavers using one of three implants: Nano Corkscrew FT 1.7 mm suture anchor (Group 1; Arthrex, Inc., Naples, FL; n = 6), Mitek Micro 1.3 mm suture anchor (Group 2; Mitek Surgical Products, Westwood, MA; n = 6), or pullout suture button fixation (Group 3; n = 6). Constructs were preloaded before testing load to failure. For each trial, elongation at 20 N and maximum load, mean load to failure, stiffness, and failure mechanism were recorded. Results Load to failure occurred in all trials. Mean load to failure was significantly greater for Group 1 (61.6 ± 18.9 N) compared to Group 2 (42.5 ± 4.2 N; p < 0.05) and Group 3 (41.6 N ± 8.0 N; p < 0.05). Stiffness was significantly greater in Groups 1 and 2 compared to Group 3 (6.9 ± 2.2 N/mm vs. 6.1 ± 0.8 N/mm vs. 3.1 N/mm ± 0.5 N/mm, respectively, p < 0.01). Mechanism of failure differed between the groups: Group 1 broke at the anchor in two trials and tore through the tendon in three trials, Group 2's suture universally broke at the anchor, and Group 3's trials mainly failed at the button. Conclusions The Nano Corkscrew anchor (Group 1) has a significantly higher load to failure when compared with the other techniques. The higher load to failure of the corkscrew anchor provides a secure method for flexor tendon repair in zone I. Clinical Relevance A fully threaded titanium suture anchor used for FDP tendon avulsion injuries is likely to withstand early active range of motion protocols.

About this research paper

What this paper is about

Purpose Multiple repair techniques have been investigated for flexor digitorum profundus (FDP) tendon avulsions. The purpose of this study is to compare the biomechanical characteristics of a new fully threaded titanium suture anchor with previously examined fixation techniques. Methods Repair of FDP tendon avulsions was performed in 18 fresh-frozen cadavers using one of three implants: Nano Corkscrew FT 1.7 mm suture anchor (Group 1; Arthrex, Inc., Naples, FL; n = 6), Mitek Micro 1.3 mm suture anchor (Group 2; Mitek Surgical Products, Westwood, MA; n = 6), or pullout suture button fixation (Group 3; n = 6). Constructs were preloaded before testing load to failure. For each trial, elongation at 20 N and maximum load, mean load to failure, stiffness, and failure mechanism were recorded. Results Load to failure occurred in all trials. Mean load to failure was significantly greater for Group 1 (61.6 ± 18.9 N) compared to Group 2 (42.5 ± 4.2 N; p < 0.05) and Group 3 (41.6 N ± 8.0 N; p < 0.05). Stiffness was significantly greater in Groups 1 and 2 compared to Group 3 (6.9 ± 2.2 N/mm vs. 6.1 ± 0.8 N/mm vs. 3.1 N/mm ± 0.5 N/mm, respectively, p < 0.01). Mechanism of failure differed between the groups: Group 1 broke at the anchor in two trials and tore through the tendon in three trials, Group 2's suture universally broke at the anchor, and Group 3's trials mainly failed at the button. Conclusions The Nano Corkscrew anchor (Group 1) has a significantly higher load to failure when compared with the other techniques. The higher load to failure of the corkscrew anchor provides a secure method for flexor tendon repair in zone I. Clinical Relevance A fully threaded titanium suture anchor used for FDP tendon avulsion injuries is likely to withstand early active range of motion protocols.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Purpose Multiple repair techniques have been investigated for flexor digitorum profundus (FDP) tendon avulsions. The purpose of this study is to compare the biomechanical characteristics of a new fully threaded titanium suture anchor with previously examined fixation techniques. Methods Repair of FDP tendon avulsions was performed in 18 fresh-frozen cadavers using one of three implants: Nano Corkscrew FT 1.7 mm suture anchor (Group 1; Arthrex, Inc., Naples, FL; n = 6), Mitek Micro 1.3 mm suture anchor (Group 2; Mitek Surgical Products, Westwood, MA; n = 6), or pullout suture button fixation (Group 3; n = 6). Constructs were preloaded before testing load to failure. For each trial, elongation at 20 N and maximum load, mean load to failure, stiffness, and failure mechanism were recorded. Results Load to failure occurred in all trials. Mean load to failure was significantly greater for Group 1 (61.6 ± 18.9 N) compared to Group 2 (42.5 ± 4.2 N; p < 0.05) and Group 3 (41.6 N ± 8.0 N; p < 0.05). Stiffness was significantly greater in Groups 1 and 2 compared to Group 3 (6.9 ± 2.2 N/mm vs. 6.1 ± 0.8 N/mm vs. 3.1 N/mm ± 0.5 N/mm, respectively, p < 0.01). Mechanism of failure differed between the groups: Group 1 broke at the anchor in two trials and tore through the tendon in three trials, Group 2's suture universally broke at the anchor, and Group 3's trials mainly failed at the button. Conclusions The Nano Corkscrew anchor (Group 1) has a significantly higher load to failure when compared with the other techniques. The higher load to failure of the corkscrew anchor provides a secure method for flexor tendon repair in zone I. Clinical Relevance A fully threaded titanium suture anchor used for FDP tendon avulsion injuries is likely to withstand early active range of motion protocols.

Key concepts: Medicine, Avulsion, Surgery, Anatomy

Related papers

Back to paper searchBrowse research topicsOriginal source
Biomechanical Comparison of Flexor Digitorum Profundus Avulsion Repair — Research Paper | ScholarLens