2019Physical Therapy in SportOpen access

Knee and hip strength measurements obtained by a hand-held dynamometer stabilized by a belt and an examiner demonstrate parallel reliability but not agreement

Lidiane Lima Florêncio, Jaqueline Martins, Marcelo Rodrigues Barbosa da Silva, Janaina R. da Silva, Gustavo Luís Bellizzi, Débora Bevilaqua‐Grossi

Open full text 41 citations

Abstract

OBJECTIVES: To verify the intrasession reliability and the agreement between strength measurement of hip and knee muscles using hand-held dynamometer stabilized by a belt or by an examiner. DESIGN: Test-retest design. SETTING: Knee and hip muscles strength were measured bilaterally using hand-held dynamometer stabilized by a belt and by an examiner. PARTICIPANTS: 24 young and healthy participants. MAIN OUTCOME MEASURES: and the standard error of measurement. Agreement between stabilization methods was verified by the Bland Altman's method. RESULTS: Reliability was excellent for all muscle groups when stabilized by a belt (intraclass correlation coefficient = 0.78 to 0.95) and by the examiner (intraclass correlation coefficient = 0.83 to 0.97); standard error of measurement ranged between 1kgf to 4kgf at both methods, but they are proportionally lower when stabilized by the examiner. No agreement between both methods was identified for all knee strength measurements and for bilateral hip flexion, right internal and external rotation and left adduction. CONCLUSIONS: The hand-held dynamometer is reliable for hip and knee strength evaluation despite of the stabilization method. However, for the majority of the movements, greater strength and lower error are expected when the examiner stabilizes it.

About this research paper

What this paper is about

OBJECTIVES: To verify the intrasession reliability and the agreement between strength measurement of hip and knee muscles using hand-held dynamometer stabilized by a belt or by an examiner. DESIGN: Test-retest design. SETTING: Knee and hip muscles strength were measured bilaterally using hand-held dynamometer stabilized by a belt and by an examiner. PARTICIPANTS: 24 young and healthy participants. MAIN OUTCOME MEASURES: and the standard error of measurement. Agreement between stabilization methods was verified by the Bland Altman's method. RESULTS: Reliability was excellent for all muscle groups when stabilized by a belt (intraclass correlation coefficient = 0.78 to 0.95) and by the examiner (intraclass correlation coefficient = 0.83 to 0.97); standard error of measurement ranged between 1kgf to 4kgf at both methods, but they are proportionally lower when stabilized by the examiner. No agreement between both methods was identified for all knee strength measurements and for bilateral hip flexion, right internal and external rotation and left adduction. CONCLUSIONS: The hand-held dynamometer is reliable for hip and knee strength evaluation despite of the stabilization method. However, for the majority of the movements, greater strength and lower error are expected when the examiner stabilizes it.

Why it matters

OpenAlex reports 41 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVES: To verify the intrasession reliability and the agreement between strength measurement of hip and knee muscles using hand-held dynamometer stabilized by a belt or by an examiner. DESIGN: Test-retest design. SETTING: Knee and hip muscles strength were measured bilaterally using hand-held dynamometer stabilized by a belt and by an examiner. PARTICIPANTS: 24 young and healthy participants. MAIN OUTCOME MEASURES: and the standard error of measurement. Agreement between stabilization methods was verified by the Bland Altman's method. RESULTS: Reliability was excellent for all muscle groups when stabilized by a belt (intraclass correlation coefficient = 0.78 to 0.95) and by the examiner (intraclass correlation coefficient = 0.83 to 0.97); standard error of measurement ranged between 1kgf to 4kgf at both methods, but they are proportionally lower when stabilized by the examiner. No agreement between both methods was identified for all knee strength measurements and for bilateral hip flexion, right internal and external rotation and left adduction. CONCLUSIONS: The hand-held dynamometer is reliable for hip and knee strength evaluation despite of the stabilization method. However, for the majority of the movements, greater strength and lower error are expected when the examiner stabilizes it.

Key concepts: Dynamometer, Reliability (semiconductor), Physical medicine and rehabilitation, Physical therapy, Medicine, Engineering, Mechanical engineering, Physics

Related papers

Back to paper searchBrowse research topicsOriginal source
Knee and hip strength measurements obtained by a hand-held dynamometer stabilized by a belt and an examiner demonstrate parallel reliability but not agreement — Research Paper | ScholarLens