Флуоресцентный микроскопический анализ жизнеспособности ооцитов млекопитающих после витрификации-=SUP=-*-=/SUP=-
Е. В. Абакушина, Ю.В. Гельм, А.С. Миценык
Abstract
Open-access reader
Е. В. Абакушина, Ю.В. Гельм, А.С. Миценык
Abstract
Open-access reader
AbstractThe paper reports the results of a fluorescent microscopy analysis of the viability of oocytes from cattle and pigs after vitrification. Oocytes were frozen in a vitrification media containing varying concentrations of cryoprotectors in several steps with subsequent vitrification. After cryobank storage for 14 days, experimental samples were thawed and oocyte viability was analyzed by oocyte morphology assessment and fluorescent microscopy. Two different kits were used to stain oocytes, one specific for necrosis/apoptosis (Propidium iodide/Alexa Fluor 488 Annexin) and the other specific for live/dead cells (Calcein-AM/ethidium homodimer-1). Fluorescent microscopy of porcine and bovine oocytes has demonstrated that the fluorescent dye Calcein-AM should be chosen to assess oocyte viability, since Propidium iodide and ethidium homodimer-1 do not represent the oocyte cell death. Therefore, Propidium iodide and ethidium homodimer-1 cannot serve as indicators of real oocyte death.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
AbstractThe paper reports the results of a fluorescent microscopy analysis of the viability of oocytes from cattle and pigs after vitrification. Oocytes were frozen in a vitrification media containing varying concentrations of cryoprotectors in several steps with subsequent vitrification. After cryobank storage for 14 days, experimental samples were thawed and oocyte viability was analyzed by oocyte morphology assessment and fluorescent microscopy. Two different kits were used to stain oocytes, one specific for necrosis/apoptosis (Propidium iodide/Alexa Fluor 488 Annexin) and the other specific for live/dead cells (Calcein-AM/ethidium homodimer-1). Fluorescent microscopy of porcine and bovine oocytes has demonstrated that the fluorescent dye Calcein-AM should be chosen to assess oocyte viability, since Propidium iodide and ethidium homodimer-1 do not represent the oocyte cell death. Therefore, Propidium iodide and ethidium homodimer-1 cannot serve as indicators of real oocyte death.
Key concepts: Propidium iodide, Calcein, Oocyte, Alexa Fluor, Vitrification, Fluorescence microscope, Annexin, Andrology