2019Assistive TechnologyRequires access

Functional electrical stimulation compared with ankle-foot orthosis in subacute post stroke patients with foot drop: A pilot study

Naama Karniel, Eitan Raveh, Isabella Schwartz, Sigal Portnoy

Open publisher page 20 citations

Abstract

Background: The conventional treatment for foot drop includes an ankle-foot orthosis (AFO) or functional electrical stimulation (FES).Goal: To compare gait parameters in patients following a subacute post stroke with foot drop treated with AFO or FES.Method: Twenty one subacute patients with stroke with foot drop were fitted with FES (N = 10) or AFO (N = 11). Evaluations were performed at baseline, following 4 weeks and 12 weeks. Spatiotemporal gait parameters and symmetry, dynamic electromyography, 10-m walk test, 6-min walk test, timed up and go, functional ambulation classification, and perception of improvement in walking were measured. The gait analysis measures were collected without the assistive devices while the functional measures were collected with them.Results: Both groups showed improvement in all of the outcome measures, with no between-groups differences. The swing duration’s and step length’s symmetry indicated better gait symmetry in the FES group after 12 weeks (p = 0.037, effect size = −0.538 and p = 0.028 effect size = −0.568, respectively). The FES group perceived significant improvement in gait after 4 weeks, while subjects in the AFO group reported to perceive improvement only after 12 weeks.Conclusions: Our findings suggest that FES is at least as effective as traditional AFO and may be more so.

About this research paper

What this paper is about

Background: The conventional treatment for foot drop includes an ankle-foot orthosis (AFO) or functional electrical stimulation (FES).Goal: To compare gait parameters in patients following a subacute post stroke with foot drop treated with AFO or FES.Method: Twenty one subacute patients with stroke with foot drop were fitted with FES (N = 10) or AFO (N = 11). Evaluations were performed at baseline, following 4 weeks and 12 weeks. Spatiotemporal gait parameters and symmetry, dynamic electromyography, 10-m walk test, 6-min walk test, timed up and go, functional ambulation classification, and perception of improvement in walking were measured. The gait analysis measures were collected without the assistive devices while the functional measures were collected with them.Results: Both groups showed improvement in all of the outcome measures, with no between-groups differences. The swing duration’s and step length’s symmetry indicated better gait symmetry in the FES group after 12 weeks (p = 0.037, effect size = −0.538 and p = 0.028 effect size = −0.568, respectively). The FES group perceived significant improvement in gait after 4 weeks, while subjects in the AFO group reported to perceive improvement only after 12 weeks.Conclusions: Our findings suggest that FES is at least as effective as traditional AFO and may be more so.

Why it matters

OpenAlex reports 20 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background: The conventional treatment for foot drop includes an ankle-foot orthosis (AFO) or functional electrical stimulation (FES).Goal: To compare gait parameters in patients following a subacute post stroke with foot drop treated with AFO or FES.Method: Twenty one subacute patients with stroke with foot drop were fitted with FES (N = 10) or AFO (N = 11). Evaluations were performed at baseline, following 4 weeks and 12 weeks. Spatiotemporal gait parameters and symmetry, dynamic electromyography, 10-m walk test, 6-min walk test, timed up and go, functional ambulation classification, and perception of improvement in walking were measured. The gait analysis measures were collected without the assistive devices while the functional measures were collected with them.Results: Both groups showed improvement in all of the outcome measures, with no between-groups differences. The swing duration’s and step length’s symmetry indicated better gait symmetry in the FES group after 12 weeks (p = 0.037, effect size = −0.538 and p = 0.028 effect size = −0.568, respectively). The FES group perceived significant improvement in gait after 4 weeks, while subjects in the AFO group reported to perceive improvement only after 12 weeks.Conclusions: Our findings suggest that FES is at least as effective as traditional AFO and may be more so.

Key concepts: Foot drop, Functional electrical stimulation, Physical medicine and rehabilitation, Gait, Ankle, Medicine, Physical therapy, Gait analysis

Related papers

Back to paper searchBrowse research topicsOriginal source
Functional electrical stimulation compared with ankle-foot orthosis in subacute post stroke patients with foot drop: A pilot study — Research Paper | ScholarLens