2019•MATEC Web of ConferencesOpen access

Preliminary evaluation of indoor thermal comfort in Malaysia heritage mosque

Wardah Fatimah Mohammad Yusoff, Nor Haslina Ja’afar

Open full text 6 citations

Abstract

Malaysia heritage buildings are the country's architectural gems. Among them is the religious building such as mosque. The Malaysia heritage mosque is normally built in response to the local culture and environment. Unlike most of Malaysia modern mosques where air conditioning is opted as ventilation mode, the heritage mosques achieve indoor thermal comfort via the passive architectural design. Due to that, this study was executed with the purpose of investigating the indoor thermal comfort of a Malaysia heritage mosque located at traditional street in Melaka, namely Masjid Tanah. The methodology used in the study was field measurement, in which the parameters measured were the indoor and outdoor air temperatures. The field measurement was conducted for two days in the end of March and early of April 2018, from 9 am to 4 pm. The indoor predicted comfort temperature was derived using the adaptive model. The findings indicated that the measured indoor air temperatures were lower than the indoor predicted comfort temperatures at most of the time. Therefore, it shows that the passive architectural design adopted by the Malaysia heritage mosque, which is Masjid Tanah, is able to provide indoor thermal comfort to the users.

Open-access reader

About this research paper

What this paper is about

Malaysia heritage buildings are the country's architectural gems. Among them is the religious building such as mosque. The Malaysia heritage mosque is normally built in response to the local culture and environment. Unlike most of Malaysia modern mosques where air conditioning is opted as ventilation mode, the heritage mosques achieve indoor thermal comfort via the passive architectural design. Due to that, this study was executed with the purpose of investigating the indoor thermal comfort of a Malaysia heritage mosque located at traditional street in Melaka, namely Masjid Tanah. The methodology used in the study was field measurement, in which the parameters measured were the indoor and outdoor air temperatures. The field measurement was conducted for two days in the end of March and early of April 2018, from 9 am to 4 pm. The indoor predicted comfort temperature was derived using the adaptive model. The findings indicated that the measured indoor air temperatures were lower than the indoor predicted comfort temperatures at most of the time. Therefore, it shows that the passive architectural design adopted by the Malaysia heritage mosque, which is Masjid Tanah, is able to provide indoor thermal comfort to the users.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Malaysia heritage buildings are the country's architectural gems. Among them is the religious building such as mosque. The Malaysia heritage mosque is normally built in response to the local culture and environment. Unlike most of Malaysia modern mosques where air conditioning is opted as ventilation mode, the heritage mosques achieve indoor thermal comfort via the passive architectural design. Due to that, this study was executed with the purpose of investigating the indoor thermal comfort of a Malaysia heritage mosque located at traditional street in Melaka, namely Masjid Tanah. The methodology used in the study was field measurement, in which the parameters measured were the indoor and outdoor air temperatures. The field measurement was conducted for two days in the end of March and early of April 2018, from 9 am to 4 pm. The indoor predicted comfort temperature was derived using the adaptive model. The findings indicated that the measured indoor air temperatures were lower than the indoor predicted comfort temperatures at most of the time. Therefore, it shows that the passive architectural design adopted by the Malaysia heritage mosque, which is Masjid Tanah, is able to provide indoor thermal comfort to the users.

Key concepts: Architectural engineering, Thermal comfort, Indoor air, Ventilation (architecture), Indoor air quality, Civil engineering, Cultural heritage, Environmental science

Related papers

Back to paper searchBrowse research topicsOriginal source
Preliminary evaluation of indoor thermal comfort in Malaysia heritage mosque — Research Paper | ScholarLens