Effect of Measurement of Dew Point Temperature in Moist Air on the Absorption Line at 1392.53 nm of Water Vapor
N. Khelifa
Abstract
Open-access reader
N. Khelifa
Abstract
Open-access reader
The HITRAN database (High-Resolution Transmission molecular absorption database) is an extremely helpful reference for selecting lines of molecular species. In the case of water vapor, a particular strong absorption line around λ ≈ 1392.5 nm is suitable for the detection of molecules, not only because of its high strength but also because it is well separated from the neighboring transitions, thus avoiding any overlap. First, we present the optical system that uses a distributed feedback (DFB) laser diode, emitting around λ ≈ 1392.5 nm with a power ≈ 3 mW and linewidth ≤ 10 MHz. For metrological needs, we are looking for a means to control the water vapor concentration in ambient air in near real time and especially when an optical chilled mirror hygrometer is used. The latter instrument is widely used due to its performance with regard to both accuracy and repeatability of measurements. Here, using the molecular absorption device the use of such an instrument is examined from the point of view of its impact on the measurement of relative humidity. This paper reports the measured frequency positions of the observed line at λ = 1392.5337 nm for different air pressures and compares them with the values given in the HITRAN database. In addition, we discuss the possibility of using water vapor detection by spectroscopy to observe the change of the shape and the position of the absorption line produced during measurements of the dew point temperature by the optical chilled mirror hygrometer.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The HITRAN database (High-Resolution Transmission molecular absorption database) is an extremely helpful reference for selecting lines of molecular species. In the case of water vapor, a particular strong absorption line around λ ≈ 1392.5 nm is suitable for the detection of molecules, not only because of its high strength but also because it is well separated from the neighboring transitions, thus avoiding any overlap. First, we present the optical system that uses a distributed feedback (DFB) laser diode, emitting around λ ≈ 1392.5 nm with a power ≈ 3 mW and linewidth ≤ 10 MHz. For metrological needs, we are looking for a means to control the water vapor concentration in ambient air in near real time and especially when an optical chilled mirror hygrometer is used. The latter instrument is widely used due to its performance with regard to both accuracy and repeatability of measurements. Here, using the molecular absorption device the use of such an instrument is examined from the point of view of its impact on the measurement of relative humidity. This paper reports the measured frequency positions of the observed line at λ = 1392.5337 nm for different air pressures and compares them with the values given in the HITRAN database. In addition, we discuss the possibility of using water vapor detection by spectroscopy to observe the change of the shape and the position of the absorption line produced during measurements of the dew point temperature by the optical chilled mirror hygrometer.
Key concepts: HITRAN, Hygrometer, Water vapor, Materials science, Dew point, Tunable diode laser absorption spectroscopy, Optics, Absorption (acoustics)