2019•Journal of Cardiovascular ElectrophysiologyRequires access

Etiology of tricuspid valve disease is a predictor of bradyarrhythmia after tricuspid valve surgery

Florian E. M. Herrmann, Helen Graf, Petra Wellmann, Sebastian Sadoni, Christian M. Hagl, Gerd Juchem

Open publisher page 12 citations

Abstract

AIMS: The tricuspid valve is situated in close proximity to cardiac conduction tissue and damage to this tissue can affect postoperative rhythm. The aim of this study was to quantify the incidence of pacemaker requirement after tricuspid valve surgery and investigate predictors. METHODS: Data were collected via our operative data collection system and patient files. All patients who underwent surgical procedures of the tricuspid valve from 2004 until 2017 and lacked a pacemaker preoperatively were included in the study. RESULTS: In our cohort of 505 patients 54 required a pacemaker in the first 50 days after surgery. We calculated a 17.5% (95% confidence interval [CI], 13.5-21.3) risk of pacemaker implantation at 4 years postoperatively. Multivariate analysis identified preoperative active endocarditis (odds ratio 3.17; CI, 1.32-7.65; P = 0.010) and "inadequate pacemaker dependent rhythm" (defined as any intrinsic heart rate below 45 per minute requiring pacing) upon admission to the intensive care unit after surgery (odds ratio 5.924; CI, 2.82-12.44; P = 0.001) as predictors for pacemaker requirement in the first 50 days after surgery. Twenty-six pacemakers (48%) were implanted for atrioventricular block, 16 (30%) for sinus node dysfunction and 12 (22%) for atrial fibrillation. Kaplan-Meier analysis showed no difference in survival between the pacemaker and no pacemaker group. CONCLUSION: Surgery of the tricuspid valve has a high burden of postoperative pacemaker requirement. Preoperative active endocarditis and the initial postoperative rhythm are predictors. Understanding this allows for better decision-making regarding further medical/device therapy.

About this research paper

What this paper is about

AIMS: The tricuspid valve is situated in close proximity to cardiac conduction tissue and damage to this tissue can affect postoperative rhythm. The aim of this study was to quantify the incidence of pacemaker requirement after tricuspid valve surgery and investigate predictors. METHODS: Data were collected via our operative data collection system and patient files. All patients who underwent surgical procedures of the tricuspid valve from 2004 until 2017 and lacked a pacemaker preoperatively were included in the study. RESULTS: In our cohort of 505 patients 54 required a pacemaker in the first 50 days after surgery. We calculated a 17.5% (95% confidence interval [CI], 13.5-21.3) risk of pacemaker implantation at 4 years postoperatively. Multivariate analysis identified preoperative active endocarditis (odds ratio 3.17; CI, 1.32-7.65; P = 0.010) and "inadequate pacemaker dependent rhythm" (defined as any intrinsic heart rate below 45 per minute requiring pacing) upon admission to the intensive care unit after surgery (odds ratio 5.924; CI, 2.82-12.44; P = 0.001) as predictors for pacemaker requirement in the first 50 days after surgery. Twenty-six pacemakers (48%) were implanted for atrioventricular block, 16 (30%) for sinus node dysfunction and 12 (22%) for atrial fibrillation. Kaplan-Meier analysis showed no difference in survival between the pacemaker and no pacemaker group. CONCLUSION: Surgery of the tricuspid valve has a high burden of postoperative pacemaker requirement. Preoperative active endocarditis and the initial postoperative rhythm are predictors. Understanding this allows for better decision-making regarding further medical/device therapy.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

AIMS: The tricuspid valve is situated in close proximity to cardiac conduction tissue and damage to this tissue can affect postoperative rhythm. The aim of this study was to quantify the incidence of pacemaker requirement after tricuspid valve surgery and investigate predictors. METHODS: Data were collected via our operative data collection system and patient files. All patients who underwent surgical procedures of the tricuspid valve from 2004 until 2017 and lacked a pacemaker preoperatively were included in the study. RESULTS: In our cohort of 505 patients 54 required a pacemaker in the first 50 days after surgery. We calculated a 17.5% (95% confidence interval [CI], 13.5-21.3) risk of pacemaker implantation at 4 years postoperatively. Multivariate analysis identified preoperative active endocarditis (odds ratio 3.17; CI, 1.32-7.65; P = 0.010) and "inadequate pacemaker dependent rhythm" (defined as any intrinsic heart rate below 45 per minute requiring pacing) upon admission to the intensive care unit after surgery (odds ratio 5.924; CI, 2.82-12.44; P = 0.001) as predictors for pacemaker requirement in the first 50 days after surgery. Twenty-six pacemakers (48%) were implanted for atrioventricular block, 16 (30%) for sinus node dysfunction and 12 (22%) for atrial fibrillation. Kaplan-Meier analysis showed no difference in survival between the pacemaker and no pacemaker group. CONCLUSION: Surgery of the tricuspid valve has a high burden of postoperative pacemaker requirement. Preoperative active endocarditis and the initial postoperative rhythm are predictors. Understanding this allows for better decision-making regarding further medical/device therapy.

Key concepts: Medicine, Tricuspid valve, Atrial fibrillation, Cardiology, Internal medicine, Odds ratio, Sinus rhythm, Endocarditis

Related papers

Back to paper searchBrowse research topicsOriginal source
Etiology of tricuspid valve disease is a predictor of bradyarrhythmia after tricuspid valve surgery — Research Paper | ScholarLens