CALSPEC: WFC3 IR Grism Spectrophotometry
R. C. Bohlin, Susana E. Deustua
Abstract
Open-access reader
R. C. Bohlin, Susana E. Deustua
Abstract
Open-access reader
The collections of spectral energy distributions (SEDs) in the \emph{Hubble Space Telescope} (HST) CALSPEC database are augmented by 19 IR SEDs from Wide Field Camera 3 (WFC3) IR grism spectra. Together, the two IR grisms, G102 and G141, cover the 0.8--1.7~\micron\ range with resolutions R=200 and 150, respectively. These new WFC3 SEDs overlap existing CALSPEC Space Telescope Imaging Spectrograph (STIS) standard star flux distributions at 0.8-1~\micron\ with agreement to $\lesssim$1\%. Some CALSPEC standards already have near-IR camera and multi-object spectrogragh (NICMOS) SEDs; but in their overlap region at 0.8--1.7~\micron, the WFC3 data have better wavelength accuracy, better spectral resolution, better repeatability, and, consequently, better flux distributions of $\sim$1\% accuracy in our CALSPEC absolute flux SEDs vs. $\sim$2\% for NICMOS. With the improved SEDs in the WFC3 range, the modeled extrapolations to 32~\micron\ for JWST flux standards begin to lose precision longward of the 1.7~\micron WFC3 limit, instead of at the 1.0~\micron\ long wavelength limit for STIS. For example, the extrapolated IR flux longward of 1.7~\micron\ for 1808347 increases by $\sim$1\% for the model fit to the data with WFC3, instead of just to the STIS SED alone.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The collections of spectral energy distributions (SEDs) in the \emph{Hubble Space Telescope} (HST) CALSPEC database are augmented by 19 IR SEDs from Wide Field Camera 3 (WFC3) IR grism spectra. Together, the two IR grisms, G102 and G141, cover the 0.8--1.7~\micron\ range with resolutions R=200 and 150, respectively. These new WFC3 SEDs overlap existing CALSPEC Space Telescope Imaging Spectrograph (STIS) standard star flux distributions at 0.8-1~\micron\ with agreement to $\lesssim$1\%. Some CALSPEC standards already have near-IR camera and multi-object spectrogragh (NICMOS) SEDs; but in their overlap region at 0.8--1.7~\micron, the WFC3 data have better wavelength accuracy, better spectral resolution, better repeatability, and, consequently, better flux distributions of $\sim$1\% accuracy in our CALSPEC absolute flux SEDs vs. $\sim$2\% for NICMOS. With the improved SEDs in the WFC3 range, the modeled extrapolations to 32~\micron\ for JWST flux standards begin to lose precision longward of the 1.7~\micron WFC3 limit, instead of at the 1.0~\micron\ long wavelength limit for STIS. For example, the extrapolated IR flux longward of 1.7~\micron\ for 1808347 increases by $\sim$1\% for the model fit to the data with WFC3, instead of just to the STIS SED alone.
Key concepts: Grism, Wide Field Camera 3, Physics, Space Telescope Imaging Spectrograph, Astrophysics, Flux (metallurgy), Lyman limit, Spectral density