2018Institutional Repositories DataBase (IRDB)Open access

RF Monitor System for SuperKEKB Injector Linac

Hiroaki Katagiri, M. Akemoto, Dai Arakawa, T. Matsumoto, Takako Miura, Feng Qiu, Y. Yano

Open full text 0 citations

Abstract

A new radio frequency (RF) monitor system for the SuperKEKB project has been developed at the KEK in-jector linac. The RF monitor unit, which consists of an analog I/Q demodulator, ADC/DAC board, and FPGA board achieved 50-Hz data acquisition and beam mode identification. On the RF monitor, the amplitude and phase measurement precision has achieved 0.1% rms and 0.1° rms, respectively. Sixty RF monitor units have been installed in the linac. The present status of the RF monitor system will be re-ported.

About this research paper

What this paper is about

A new radio frequency (RF) monitor system for the SuperKEKB project has been developed at the KEK in-jector linac. The RF monitor unit, which consists of an analog I/Q demodulator, ADC/DAC board, and FPGA board achieved 50-Hz data acquisition and beam mode identification. On the RF monitor, the amplitude and phase measurement precision has achieved 0.1% rms and 0.1° rms, respectively. Sixty RF monitor units have been installed in the linac. The present status of the RF monitor system will be re-ported.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new radio frequency (RF) monitor system for the SuperKEKB project has been developed at the KEK in-jector linac. The RF monitor unit, which consists of an analog I/Q demodulator, ADC/DAC board, and FPGA board achieved 50-Hz data acquisition and beam mode identification. On the RF monitor, the amplitude and phase measurement precision has achieved 0.1% rms and 0.1° rms, respectively. Sixty RF monitor units have been installed in the linac. The present status of the RF monitor system will be re-ported.

Key concepts: Linear particle accelerator, Injector, Environmental science, Physics, Engineering, Beam (structure), Optics, Mechanical engineering

Related papers

Back to paper searchBrowse research topicsOriginal source